Item number
Item
506
DRUM ROTATION
TIMER

Items Relating to the Time Code (Nos. 601 to ...)

Item number
Item
601
DF/NDF MODE
select
602
TIMER MODE
select
603
TCR MODE select
604
TC2 MODE SEL
Setting
Function
1H
When menu item 502 or 503 set to "tension release", or
2H
when menu item 504 is set to "on", the drum motor of this
3H
unit continues to rotate after tension release mode is
[4H]
entered.
8H
This menu item sets the time until the unit enters standby
off mode and the drum motor stops rotating after entering
tension release mode.
The selectable time ranges from one to eight hours.
Setting
Function
[drop frame]
Selects the running mode for the time code after frame
non-drop frame
conversion and the CTL counter.
auto
drop frame: drop frame mode ("DF" indication)
non-drop frame: non-drop frame mode ("NDF" indication)
auto: Drop frame / non-drop frame mode is selected
Note
This setting is only active when the frame frequency of the
unit is 29.97 Hz, 59.94 Hz, 30 Hz, or 60 Hz.
CTL
Selects the mode for displaying time data.
[TC]
CTL: During playback the CTL signal recorded on the tape
UBIT
TC: The time code value read by the time code reader, or
UBIT: The user bits inserted in the playback time code are
[LTC]
Selects the time code read by the time code reader during
auto
playback.
VITC
LTC: LTC is read.
auto: If the playback speed is in the range ±1/2 normal
VITC: VITC is read.
UBV
Selects the time data appearing in the second line.
UBR
UBV: Displays UBV.
CTL
UBR: Displays UBR.
VITC
CTL: Displays CTL.
auto
VITC: Displays VITC.
LTC
auto: Displays VITC when the playback speed is in the
[off]
LTC: Displays LTC.
off: Does not display time data in the second line.
automatically on the basis of the frame frequency of
the unit. For 29.97 Hz/59.94 Hz drop frame mode is
selected, and for 30 Hz/60 Hz non-drop frame mode is
selected. The setting of the frame frequency mode is
carried out with the [F9] (OTHERS CHECK)/ [F9]
(SYSTEM) button in MAINTENANCE menu.
is counted, and the tape running time is displayed in
hours, minutes, seconds, and frames.
the time code value generated by the time code
generator is displayed. Use item 603 to toggle between
VITC and LTC.
displayed. Use item 603 to toggle between VITC and
LTC.
speed, VITC is read, and if outside this range LTC is
read.
range ±1/2 normal speed, and LTC if outside this
range.