Oki Data CONFIDENTIAL

1.5 Interface specifications

1.5.1 USB interface specifications
Fundamental specifications
USB(Hi-speed USB is supported)
Connector
B-receptacle (female) upstream port
Cable
SUB 2.0 specification cable of less than 5 m (2 m is recommended.)
(Use the shielded cable.)
Transmission mode
Full speed (Maximum 12 Mbps ± 0.25%)
High speed (Maximum 480 Mbps ± 0.05%)
Power control
Self-power device
Connector pin arrangement
2
3
Interface signal
Signal name
1
Vbus
2
D-
3
D+
4
GND
Shell
Shield
43967002TH Rev.1
1
4
Function
Power (+5V)
For data transfer
For data transfer
Signal ground
1.5.2 Network interface specifications
Fundamental specifications
Network protocol
TCP/IP related
NetWare related
Ether Talk related
NetBEUI related
Connector
100 BASE-TX/10.BASE-T (Automatic switching. Simultaneous use is not possible.)
Cable
Non-shielded twist pair cable with RJ-45 connector (Category 5 is recommended.)
Connector pin arrangement
1
Interface signal
Pin No. Signal name
Direction
1
TxD+
FROM PRINTER
2
TxD-
FROM PRINTER
3
RXD+
TO PRINTER
4
5
6
RXD-
TO PRINTER
7
8
1. Configuration
8
Function
Send data (+)
Send data (-)
Receive data (+)
Not used
Not used
Receive data (-)
Not used
Not used