5.6.4 Scan position adjustment

5.6.4.1 Side registration adjustment
The separate setting items are prepared for FBS, ADF (front side) and ADF (back side)
independently.
Setting for FBS
Value
Default
+25
0
-25
-10
(+5.29mm
0
(-2.117mm)
-5.29mm)
Perform adjustment so that the scan start position in the horizontal scanning direction during
FBS scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the right.
When a value is added in the positive (+) direction, the scan image on a PC moves to the left.
Setting for ADF (front side)
Value
Default
+25
0
-25
+1
(+5.29mm
0
(+0.2117mm)
-5.29mm)
Perform adjustment so that the scan start position in the horizontal scanning direction during
ADF front side scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the left.
When a value is added in the positive (+) direction, the scan image on a PC moves to the right.
43967002TH Rev.1
Reference value
Display condition
±1.2mm
None
Reference value
Display condition
±1.8mm
None
Setting for ADF (rear side)
Value
Default
+25
0
-25
+18
(+5.29mm
0
(+3.8106mm)
-5.29mm)
Perform adjustment so that the scan start position in the horizontal scanning direction during
ADF rear side scanning stays within the reference value.
Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves to the left.
When a value is added in the positive (+) direction, the scan image on a PC moves to the right.
5.6.4.2 Top end position adjustment
The separate setting items are prepared for FBS, ADF (front side) and ADF (back side)
independently.
Setting for FBS
Value
Default
+31
0
-31
+8
(+4.36mm
0
(+1.1264mm)
-4.36mm)
Perform adjustment so that the scan start position in the vertical scanning direction during FBS
scanning stays within the reference value.
If shade is scanned at the top end of a document, make adjustment in the positive direction. If
deficiency occurs at the top end of a document, make adjustment in the negative direction.
Adjustment in increment of 1 item (0.1408 mm) is possible in this setting.
When a value is added in the negative (-) direction, the scan image on a PC moves down.
When a value is added in the positive (+) direction, the scan image on a PC moves up.
5. Maintenance Menu
Reference value
Display condition
±2.3mm
None
Reference value
Display condition
±1.2mm
None