Oki Data CONFIDENTIAL
4.2.3.12 Shaft eject Assy (FU)/Shaft eject Assy (FD)
(1) Remove the scanner. (Refer to chapter 4.2.1.)
(2) Release the hook of the link arm
(3) Remove the screw (silver)
Note! If the top cover is closed while the hooks of the stay arm L and R, and the
hooks of the link arm being released, the top cover can be damaged. Before
closing the top cover, engage the hooks of the respective parts to their original
positions. (Refer to Fig. XX.)
43967002TH Rev. 1
, stay arm L
and stay arm R
.
and disconnect the guide eject Assy upper
(4) Remove the gear idle ejects
.
(5) Remove the two mold E-ring
shaft Assy eject (FD)
and
.
, and remove the shaft Assy eject (FU)
by bending them.
4. Part Replacement
and the
168 /