E. Junction Box Installation
If the box is being wired from the OUTSIDE of the
appliance:
• Install the
Romex™
connector (not included with
appliance) in the side wrap.
• Loosen two screws on the Romex connector, feed
the necessary length of wire through the connector
and tighten the screws.
• Make all necessary wire connections.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box to
the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 7.4).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan
(See Figure 7.5):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied
from the switch box to the appli-
ance using a minimum of 14-3 with
ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire
to the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box
as shown.
• Add a 1/4 inch insulated female
connector to the red (switch leg)
wire, route it through the knockout
in the face of the junction box, and
connect to the top fan switch con-
nector (1/4 inch male) as shown.
FAN
SPEED CONTROL
(RHEOSTAT)
Figure 7.5 Junction Box Wired to Wall Switch
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. K • 9/08
HEAT SHIELD
BLK
WHT
BLK
WHT
Figure 7.4 Junction Box Detail
• Loosen the two screws on the Romex connector, feed the
necessary length of wire through the connector and tighten the
screws.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
6 INCH
APPROX.
FAN
PLUG AND WIRE
ASSEMBLY
14/2WG
COPPER GROUND
ATTACHED TO GRN SCREW
WITH GRN WIRE
GREEN WIRE
INSIDE BOX
NOTE: Do NOT wire
110 VAC to wall switch.
WIRE LEAD
1 MALE END
1 FEMALE END
TEMPERATURE
SENSOR SWITCH
WIRE LEAD
2 FEMALE ENDS
JUNCTION
6 INCH
APPROX.
OPTIONAL
WALL SWITCH
BOX