Cable Connections; Control Cable Connections; Flexible Connection Possibilities - Lincoln Electric POWER WAVE SVM135-B Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

A-7
FIGURE A.2 — CONNECTION DIAGRAM ON RECONNECT/INPUT ACCESS DOOR.
INPUT SUPPLY CONNECTION DIAGRAM
.
Disconnect input power before
inspecting or servicing machine.
.
Do not operate with covers
removed.
.
Do not touch electrically live parts.
Only qualified persons should install,
.
use or service this equipment.
VOLTAGE=220-230V
200-208V
220-230V
380-415V
440-460V

CABLE CONNECTIONS

CONTROL CABLE CONNECTIONS

• All system control cables are the same but can
vary in length.
• All control cables can be connected end to end to
extend their length.
• All system equipment must be connected to a
control cable.
Welding systems using the Power Feed 10 offer pre-
viously unprecedented flexibility in the connection of
system components. This system uses the same
type of control cable between each of the system
components. Connections can be "daisy chained"
from one system component to another. Since com-
munication over the control cables is done by a
robust communications network, the order of connec-
tion of the components makes no difference.
cables can be connected anywhere that there is a
mating connector. See the flexible connections part
of this section for more details.
NOTE: Maximum cable length between any two
nodes is 250 feet.
INSTALLATION
W / L3
V / L2
U / L1
VOLTAGE=380-415V
200-208V
220-230V
'A'
380-415V
440-460V
The
POWER WAVE 455/POWER FEED 10
VOLTAGE=200-208V
CR1
VOLTAGE=440-460V
'A'
TYPICAL BENCH FEEDER CONNECTION
Control cable is connected from Power Source (PS)
to Feed Head (FH). If the Control Box is separated
from the FH, a control cable will connect from the PS
to the control box, which will have two control cable
connectors. This could be the control box or the FH
control box depending on how the units were sepa-
rated. A second control cable would be connected
from the second connector on the control box to the
other FH control box.
TYPICAL BOOM FEEDER CONNECTION
Control cable is connected from PS to the control
box. A second control cable would be connected
from the second connector on the control box to the
FH control box.

FLEXIBLE CONNECTION POSSIBILITIES

By using connector kits, a second connector can be
added to the Control box or the FH. This allows the
user to connect equipment types together in any
order.
A-7
200-208V
220-230V
'A'
380-415V
440-460V
200-208V
220-230V
'A'
380-415V
440-460V