A-14
Setting Wire Drive Acceleration Rate Using
DIP Switch S1 on the Control Box Motherboard
Acceleration 1 (slow)
Acceleration 2
Acceleration 3
Acceleration 4
Acceleration 5 (fast ) (factory setting)
SETTING DIP SWITCHES IN THE WIRE
DRIVE
There is one DIP switch bank on the control board of
the wire drive. It's labeled S1 and is located and ori-
ented as shown in Figure A.4.
S1 DIP Switch on Wire Drive Control Board (For software version S24029-All & S24467)
Switch
Off
1
Network Group ID, MSB (Assigns Wire Drive to a specific group)
2
Network Group ID, LSB (Assigns Wire Drive to a specific group )
3
Network Feed Head ID, MSB (Assigns feed head number to wire drive)
4
Network Feed Head ID
5
Network Feed Head ID, LSB
6
Spare
7
Electrode Sense Polarity = Positive
Switch position must match polarity of weld cable attached to feed plate.
8
Gear Box Ratio = Low
Switch position must match actual gear box ratio of wire drive.
Note: the factory shipped settings for all of the S1 switches is "OFF".
INSTALLATION
DIP SWITCH 6
Off
Off
Off
On
Off
On
(Assigns feed head number to wire drive)
(Assigns feed head number to wire drive)
Electrode Sense Polarity = Negative
Gear Box Ratio = High
POWER WAVE 455/POWER FEED 10
(All software versions)
DIP SWITCH 7
DIP SWITCH 8
Off
On
On
Off
Off
ON
1
2
3
4
5
6
7
8
FIGURE A.4
A-14
On
Off
On
Off
Off