Power Feed - Lincoln Electric POWER WAVE SVM135-B Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-13

POWER FEED

Observe all Safety Guidelines detailed throughout this manual.
PROBLEMS
(SYMPTOMS)
Major physical or electrical dam-
age is evident when the sheet
metal cover(s) are removed.
No wire feed, solenoid or arc volt-
age.
The STATUS LEDs are
steady green.
No control of wire feed speed. All
STATUS LEDs are steady green.
The preset wire feed speed is
adjustable on the Control Box.
No welding arc voltage when the
gun trigger is activated. The wire
feeds normally and the gas sole-
noid functions properly.
STATUS LEDs are steady green
on the wire drive unit and the
Contol Box.
The wire feed speed does not
change when welding current is
established. The WFS stays at the
run-in speed. The STATUS LEDs
are steady green.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
-----------------------------------------------------------------------------------------------------------------------------
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
FUNCTION PROBLEMS
1. Contact your local authorized
Lincoln Electric Field Service
Facility for technical assistance.
1. The gun trigger may be faulty.
Check or replace.
2. Make certain the Control Box is
configured for a wire feeding
mode.
3. Check option panel connec-
tions and switch(s) for proper
operation.
1. Check for a mechanical restric-
tion in the wire feed path.
1. The power source may unable
to produce welding output due
to a thermal fault or other mal-
The
function. Check STATUS LED
on Power Wave 455 machine.
See
Power
Troubleshooting.
1. The run in and weld wire feed
speeds may be set to the same
value. Set run in speed to a
value that gives best starting
results.
CAUTION
POWER WAVE 455/POWER FEED 10
RECOMMENDED
COURSE OF ACTION
1. Contact the Lincoln Electric
Service Department, 216-383-
2531
(WELD).
1. Check the continuity of leads
#556 and #557 from the gun
trigger receptacle to plug J5
pins #11 and #12. See wire
drive wiring diagram.
2. The wire drive control board
may be faulty.
3. The Control Box control board
may be faulty.
1. Perform the Tach Feedback
Test.
2. The wire drive control board
may be faulty.
1. Make certain the Power Wave
455 power source is function-
ing correctly.
2. The wire drive control board
Wave
455
may be faulty.
3. The Control Box control board
may be faulty.
1. Perform the Current Trans-
ducer Test.
2. If the run in wire feed speed
cannot be adjusted, perform the
Tach Feedback Test and also
the Drive Motor Test.
3. The wire drive control board
may be faulty.
F-13
or
1-800-833-9353

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 455Power feed 10

Table of Contents