Trigger - Generic Trigger X 50ccm Owner's Manual

Table of Contents

Advertisement

6.5.3 Secondary coil
Measure the resistance value between the wire of spark plug
cover (with the spark plug) and the terminal.
Standard value :8-11KΩ(20 )
If the resistance value is within standard value range, the
primary coil is good.
The resistance value "∞" stands for broken line in the coil.
Remove the spark plug cover and measure the resistance
value between the primary wire of ignition coil and the
negative terminal.
Standard value :4.5-5.5KΩ(+/-)10%(20 )

6.6 Trigger

*Note
Inspection of the trigger can be conducted on
the engine.
Inspection
Disassemble the body guard.
Disassemble the lead connector of the trigger.
Measure the resistance value between the blue/white
terminal at the engine side and the body ground.
Standard value :100-200Ω(20 )
If the measured value exceeds the standard value, replace the
alternator.
磁电机接口
magnetor connector
black
sleeve
护套
termina
端子
waterproof bolt
防水栓 MFD006-4
- 67 -
ignition line figure
点火线图
Ω
Ω
蓝\白
brown
蓝/白
blue/white
white
DJ7041-1.5-21
DJ624-1.8A

Hide quick links: