Preparation Data; Ignition System - Generic Trigger X 50ccm Owner's Manual

Table of Contents

Advertisement

6 Ignition system

Preparation data ---------------------- 6.1

Fault diagnosis ----------------------- 6.2
Ignition system inspection --------- 6.3
CDI group ---------------------------- 6.4
6.1 Preparation data
Matters needing attention in operation
1. Inspect the ignition system in accordance with the order stipulated in the fault diagnosis table.
2. The ignition system is an electronic auto-advance device integrated in the CDI group, therefore the ignition
time needs no adjustment.
3. Inspect the ignition system in accordance with the order stipulated in the fault diagnosis table.
4.Take particular care in disassembly that the CDI group of ignition system should not fall off and drop down
or should not stricken with might(which is the main cause of fault)
5. Bad socket contact is the main cause of the ignition system fault, so inspect whether the joint of each part is
in poor contact or not.
6. Inspect whether the spark plug is utilized at a proper thermal value. Improper spark plug may lead to
unsmooth operation of engine or burn-out of the spark plug.
7. Inspection in the chapter is based on explanation of peak voltage and the judgment whether the resistance
value of ignition coil is OK or not according to records after the inspection.
8. Inspection of the main switch should be performed in accordance with the conduction table.
9. The disassembly of the alternator and stator should be conducted in accordance with the disassembly
explanation.
Preparation reference
Recommended
spark plug
Spark plug gap
resistance
value of
Secondary
ignition coil
coil
(20 )
resistance value of the trigger(20 )
measured peak voltage of ignition coil at one go
Trigger voltage
Tools
Accessory of peak voltage meter
Avometer
Item
Standard
Hard plug
Soft plug
Primary coil
with plug cover
without plug cover
Ignition coil -------------------- 6.5
Trigger -------------------------- 6.6
Charge coil --------------------- 6.7
Standard value
C5HSA(NGK)
C6HSA(NGK)
C7HSA(NGK)
0.5-0.7mm
0.4Ω(+/-)10%
8-11KΩ
4.5-5.5KΩ
100-200Ω
95-400V
1.7V or above
- 62 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents