Measuring range by the variable range marker (VRM)

There are two VRMs, No. 1 and No. 2, which appear as dashed rings so that you
can distinguish them from the fixed range rings. The two VRMs can be
distinguished from each other by the different lengths of their dashes; the
dashes on the No. 2 VRM are longer.
By keyboard
1. Press the [VRM ON] key to display either of the VRMs. Successively
pressing the [VRM ON] key toggles the active VRM between No. 1 and No. 2.
The currently active marker is enclosed with >...<.
2. Operate the VRM rotary control to align the active variable range marker with
the inner edge of the target of interest and read its distance at the lower-right
corner of the screen. Each VRM remains at the same geographical distance
when you operate the [RANGE] key or the RANGE box. This means that the
apparent radius of the VRM ring changes in proportion to the selected range
scale.
3. Press the [VRM OFF] key to erase each VRM.
By trackball
1. Use the trackball to place the arrow in the VRM1 or VRM2
box, whichever VRM you want to use.
2. The guidance box reads "VRM ON/." Push the left button
to turn on the VRM. The guidance box now reads "VRM SET L = DELETE /."
3. Push the left button again and the cursor jumps to inside the effective display
area. The guidance box now reads "VRM FIX / EXIT."
4. Use the trackball (coarse adjustment) or scrollwheel (fine adjustment) to
align the active variable range marker with the inner edge of the target of
interest and read its distance at the lower-right corner of the screen. Each
VRM remains at the same geographical distance when you operate the
[RANGE] key. This means that the apparent radius of the VRM ring changes
in proportion to the selected range scale.
5. Push the left button to anchor the VRM and fix its readout, or push the right
button to return the VRM to its previous location (range).
6. To erase a VRM, select the appropriate VRM readout box then push the left
button until the VRM disappears from the screen.
1-32
000
350
010
340
020
330
030
No. 1
320
VRM
310
300
290
280
270
260
250
240
230
220
210
150
200
160
190
170
180
45:02
99:59
TTG to VRM
Measuring range with VRMs
Target
040
blip
050
060
070
080
090
100
No. 2
110
VRM
120
130
140
>0.66NM<
VRM1
1.18NM
VRM2
VRM1
VRM2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Far-21 series

Table of Contents