Electrical Information; Wiring Requirements; Intellifire Plus; Tm Ignition System Wiring - Heat & Glo SUPREME-N-I30AU Owner's Manual

Hide thumbs Also See for SUPREME-N-I30AU:
Table of Contents

Advertisement

10
10

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be installed by a qualifi ed
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction box to 220-240 VAC. This is
required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
220/240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The main supply to the appliance must have
isolation of a minimum 1/8 in. (3 mm) contact separation
in both poles.
WARNING! Risk of Injury! The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
RC100 6V DC
(CR2032 X 2)
(WALL SWITCH)
GROUND
TO CHASSIS
TO AUX300CE
6V DC SUPPLY
DC REGULATOR
220/240 V
INCOMING POWER
Figure 10.1 IPI Wiring Diagram RC300AU
RC300 4.5V DC
(AAA X 3)
GAS TUBE
FLAME
SENSE
CONTROL MODULE
8K1 WIRE
HARNESS
ORANGE
GREEN
BLACK
(PILOT)
(MAIN)
BROWN
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. X • 6/14
B. IntelliFire Plus
• Wire the appliance junction box to 220-240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 10.1, IPI Plus Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance OR install 4 C cell
batteries (not included) into the battery pack before use.
• An in-line isolation switch (per AS5601) must be installed
within 1 meter of the fi replace. This is required for servic-
ing and/or resetting the control module in the event of a
control module LOCK-OUT.
IGNITOR
I
AUX300CE MODULE
S
RED
GROUND
EMC FILTER UNIT
GROUND
TM
Ignition System Wiring
240V FAN
FAN
AUX 1 AUX 2
TO OPTIONAL
COMPONENTS
OPTIONAL ON/OFF
WALL SWITCH
BATTERY PACK
6V DC (C X 4)
TM
TO JUNCTION
CORD 230 VAC
37