TABLE 1
MODEL
SUPREME-N-I30AU, SUPREME-P-I30AU
TERMINATION CAP
EXHAUST
COLLAR
WARNING:
THE EXHAUST PIPE
MUST ONLY BE CONNECTED TO THE
EXHAUST STARTING COLLAR OF THE
UNIT AND THE EXHAUST COLLAR OF
THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY
BE CONNECTED TO THE INLET AIR
COLLAR OF THE UNIT AND ATTACHED
TO THE INLET AIR COLLAR OF THE
TERMINATION CAP. THE APPLIANCE
WILL NOT OPERATE PROPERLY IF
INCORRECTLY CONNECTED.
THIS IS A BALANCED FLUE HEATER
AND REQUIRES THE USE OF
BOTH FLUE LINERS AND MUST
TERMINATE TO THE CAP.
Figure 8.8
LINK-DV30B
CHIMNEY PLATE
(MADE TO ORDER)
INLET AIR
COLLAR
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. X • 6/14
FLUE TERMINATION APPROVAL
VERTICAL TERMINATION CAP
SLP-TVHW
FLEXIBLE FLUE
MINIMUM TOTAL FLUE
RUN 10 ft. (3 m)
MAXIMUM 39 ft. (12 m)
MINIMUM 1/4 in. (6 mm )
NON-COMBUSTIBLE BASE (UNDER UNIT)