Heat & Glo SUPREME-N-I30AU Owner's Manual page 30

Hide thumbs Also See for SUPREME-N-I30AU:
Table of Contents

Advertisement

Note: The header can only be installed in an existing masonry
chase or equivalent non-combustible enclosure. Clearances
around and above pipe must be adhered to.
SLP-TRAP
NOTE: Any 3 in. (76 mm) section
of fl ex pipe must be enclosed to
existing fi replace fl ue in double
l i n e d f l u e t o c o m p l y w i t h
AS2918-2001 and the building
code of Australia.
Seal connection points for ducting.
NOTE: Tape all SLP pipe connec-
tions with aluminum foil tape rated
to a minimum of 149 °C (300 °F).
Figure 8.13 Optional SLP venting confi guration - Horizontal Termination
30
11-7/8 in.
(600 mm)
MAXIMUM
10 ft. (3 m)
MINIMUM
FLEXIBLE FLUE
MIN. 35-7/16 ft.
(900 mm)
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. X • 6/14
Note: Adhere to AS5601 plumbers code for minimum clearances
for termination of balanced fl ue appliances.
Must adhere to pipe clearances.
SLP 90° BEND
Colinear to Coaxial Adapter
LINK ADAPTER
225 & 275 Ø
GALVANIZED FLUE
STARTER PLATE