Heat & Glo ESC-42ST Owner's Manual

Heat & glo esc-42st gas fireplace
Hide thumbs Also See for ESC-42ST:
Table of Contents

Advertisement

Quick Links

Model:
ESC-42ST
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo ESC-42ST

  • Page 1 Technologies suggests NFI certifi ed or factory trained professionals, or technicians supervised by an NFI gases, unless a certifi ed kit is used. certifi ed professional. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 3: Table Of Contents

    D. Elevated Hearth Systems ......45 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 4 D. Contact Information ......67  = Contains updated information. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 9: User Guide

    • Keep remote controls out of reach of children. • Never leave children alone near a hot fi replace, whether operating or cooling down. • Teach children to NEVER touch the fi replace. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information, refer to the instructions supplied with your decorative door or front. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 11: Ipi Battery Tray/Battery Installation

    Batteries should only be installed for use during power WARNING! Risk of Fire or Asphyxiation! DO NOT op- outages. See Section G. erate fi replace with fi xed glass assembly removed. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 12: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 13: After Fireplace Is Lit

    Noise is caused by metal expanding and contracting as it heats up and cools down, similar to Metallic noise the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the fi replace. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 14: Maintenance And Service

    Section 6. • Inspect for corrosion or separation. • Verify weather stripping, sealing and fl ashing remains intact. • Inspect draft shield to verify it is not damaged or missing. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 15: Maintenance Tasks-Qualifi Ed Service Technician

    • Verify air shutter setting is correct. See Section 14 for attachment components are intact and not damaged. required air shutter setting. Verify air shutter is clear of Replace as necessary. dust and debris. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 16 Replace pilot as necessary. Figure 3.1 IPI Pilot Flame Patterns Light Bulb Maintenance Frequency: As needed By: Qualifi ed Service Technician Tools needed: Protective gloves, replacement light bulbs. • See Section 14.F. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 17: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.B AND 8.C) FRAMING/HEADER (SECTION 5) MANTEL AND MANTEL LEG (SECTION 5.D) HEARTH EXTENSION (SECTION 5.) GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 18: Design And Installation Considerations

    Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 19: Framing And Clearances

    36 IN. 13 IN. TO FIREPLACE OPENING 13 IN. NOTE: 1/2 IN. THICK FACTORY- SUPPLIED NON-COMBUSTIBLE 36 IN. BOARD NOT SHOWN ATTACHED TO APPLIANCE. Figure 5.1 Appliance Locations Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 20: Constructing The Appliance Chase

    ** Fireplace may need to be elevated from the fl oor affecting framing height B, depending on hearth construction. See Section 5.E for hearth and combustible fl oor requirements. Figure 5.2 Clearances to Combustibles Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 21: Mantel And Wall Projections

    13 IN. MIN. NON-COMBUSTIBLE MATERIAL FIREPLACE OPENING Figure 5.4 Clearances to Mantels or other Non-Combustibles Above Appliance NON-COMBUSTIBLE WALL Figure 5.6 Clearances to Non-Combustible Mantel Legs or Wall Projections. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 22: Hearth Extension

    FLOOR OR PLATFORM Figure 5.8 Fireplace Raised A Minimum of 3 Inches Above Combustible Surface 60-1/4 1530 Figure 5.10 Non-Combustible Hearth Extension Minimum Dimensions (Fireplace Positioned on Combustible Surface) Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 23: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 24 Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 25: Vent Information And Diagrams

    45º elbows DVP36 (see Figure 7.1). DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 26: Vent Diagrams

    • This appliance requires a minimum of 24 inches of verti- cal pipe attached directly to the appliance starting collar before attaching a 90 degree or 45 degree elbow. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 27 20 ft 6.1 m After V = 6 ft then H = 2 x V ft Maximum = 60 ft Maximum = 20 ft Maximum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 28 EXCEPT, = 2 x V and V cannot exceed 60 ft Maximum t max total total Figure 7.5 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 29 *No specifi c restrictions on this value EXCEPT elbow to the appliance. cannot exceed 60 ft (18.3 m). After V = 6 ft, then H Max.= V Figure 7.7 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 30 6.1 m and H has no specifi c restrictions EXCEPT, after V = 6 ft, then H Max = 2 x V = 60 ft Max. INSTALLED HORIZONTALLY Figure 7.8 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 31: Vent Clearances And Framing

    (1) in. (25.4 mm) above the center of the horizontal vent pipe. side of an interior wall. A minimum 1-1/2 in. (38 mm) Figure 8.2 Wall Penetration overlap of attached heat shields must be maintained. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 32: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 33: Appliance Preparation

    1/4 in. screws fastening the non-com- bustible assemblies to the appliance. See Figure 9.3. MESH RODS (2) MESH RODS (2) Figure 9.5 Mesh Rod Location, Gas Valve Side of Appliance. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 34: Securing And Leveling The Appliance

    NON-COMBUSTIBLE BOARD FINISHING STRIPS Figure 9.7 Attaching Non-Combustible Board Figure 9.8 Proper positioning, leveling and securing of an appliance Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 35: Installing Vent Pipe

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 36: Assemble Slip Sections

    NOTICE: If slip section is too long, the inner and outer fl ues of the slip section can be cut to the desired length. Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 37: Disassemble Vent Sections

    Figure 10.11. • Pull carefully to separate the pieces of pipe. Figure 10.10 Rotate Seams for Disassembly Figure 10.11 Align and Disassemble Vent Sections Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 38: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 39: Install Vertical Termination Cap

    A minimum 1-1/2 in. (38 mm) overlap MUST be maintained. • Use an extended heat shield if the fi nished wall thickness is greater than 7-1/4 in. (184 mm). Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 40: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 41: Electrical Information

    • This appliance is equipped with an Intellifi re control valve which operates on a 6 volt system. JUNCTION BOX ELECTRICAL ACCESS HOLE SCREWS ELECTRICAL COMPONENT ACCESS PLATE Figure 12.1 Junction Box Detail Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 42 SENSE TO JUNCTION BOX (110-120 VAC) MODULE AUX300 MODULE DO NOT USE AUX2 FOR LIGHT CONNECTION PROTECTIVE COVER INCLUDED TO JUNCTION BOX 110-120 VAC Figure 12.2 IPI Wiring Diagram Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 43: Finishing

    MANTEL LEG MATERIAL 13 IN. MIN. FIREPLACE OPENING Figure 13.2 Clearances to Mantels or other Non-Combustibles Above Appliance NON-COMBUSTIBLE WALL Figure 13.4 Clearances to Non-Combustible Mantel Legs or Wall Projections. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 44: Facing Material

    47-1/8 in. the fi nishing material fl ush with the fi rescreen. This is not required. NON-COMBUSTIBLE BOARD Figure 13.6 Noncombustible Facing Diagram Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 45: Elevated Hearth Systems

    The above listed Hearth and Home Technologies manufactured hearth systems have been tested and certifi ed for use with the ESC-42ST fi replace. The dimensions of these Hearth and Home Technologies manufactured hearth systems may differ slightly from the mantel specifi cations listed in Section 5.D and Section 13.A. The above listed Hearth and Home Technologies manufactured hearth systems are not required to meet the mantel specifi...
  • Page 46: Appliance Setup

    Engage an end latch fi rst, then middle latch, and fi nally Figure 14.2 . the last end latches. HANDLE Figure 14.4 Glass Latch Engaged into Frame Latch. Figure 14. 2 Initial Positioning of Frame into Opening. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 47: Remove The Shipping Materials

    Gas Kit instructions for the ® remaining installations steps. Figure 14.6 Top Glass Latch Access GLASS FRAME REFRACTORY HEAT-ZONE ® KNOCKOUTS Figure 14.8 Heat-Zone® Gas Knockouts. Figure 14.7. Top Glass Latch Detail Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 48: Install Light Bulbs

    1. Remove the screw that secures the two bottom sheet metal refractory standoffs that are installed around the left and right accent light assemblies. See Figure 14.13. Figure 14.13 Accent Light Bulb Installation Completed Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 49: Install Refractory

    Figure 14.15 Refractory Clip Installation 5. Install two outer bottom refractory pieces as shown in Figure 14.18. Ensure that outer bottom refractory pieces do not extend past the outer fi rebox fl ange. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 50: Install Teco-Sil (Glass Ember Rock)

    See Figure 14.20 and Figure 14.21. Figure 14.22 Ember Placement on Base Refractory Figure 14.20 Ember Bed Painting Figure 14.21 Finished Ember Bed Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 51: Install The Log Assembly

    #1 onto the grate and pull forward so that the indentation on the front of the log engages the left grate tine. The “burnt” tip of Log #1 should rest on the burner. The log must NOT block any burner ports. See Figure 4. 2146-936C Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 52 Figure 10. Push log so that it rests against the grate tine shown in Figure 11. The “burnt” end of the log rests on the burner. The log must NOT block any burner ports. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 53 Figure 16. LOG NUMBER 9 (SRV582-707): Place log #9 onto Log #2 and Log #5. The “burnt area” of log 9 will face the pilot side of the log assembly. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 54: Ember/Mineral Wool Placement

    See Figure 14.26. 4. Install Outer Hearth. See Figure 14.27. Figure 14.27 Outer Hearth Installation Figure 14.24 Shipping Location of Refractory Brackets Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 55: Install Mesh

    • Pull the air handle out to open the air shutter. NOTICE: If sooting occurs, provide more air by opening the air shutter. Air Shutter Settings ESC-42ST 1-1/2 in. Fully Open Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 56: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 57 fi ne steel wool to remove any contaminants that may have accumulated on fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 58: Reference Materials

    Appliance Dimensions Table Location Inches Millimeters Location Inches Millimeters 9-1/8 58-1/8 1476 1067 39-7/16 1002 12-3/4 35-1/8 8 dia. 45-3/8 1153 1524 30-3/8 46-3/8 1178 Figure 16.1 Appliance Dimensions Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 59: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 60 (305 mm) 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 16.3 DVP vent components Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 61 Cap Shield 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 62 9-3/16 IN. (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profi le Cap Figure 16.5 Vent Components Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 63: Service Parts

    Service Parts Beginning Manufacturing Date: Dec 2008 42” See-thru Gas Fireplace - DV Ending Manufacturing Date: Active Log Set Assembly Refractory Assembly Part number list on following page. 05/14 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 64: Service Parts

    Mineral Wool 050-721 700-790 Teco-Sil, 5lb. Bag White Ember Bed Rock Touch Up Paint TUP-GBK-12 Twig Center SRV582-707 Vermiculite Embers MYSTIC-EMBERS Additional service part numbers appear on following page. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 65 Pre 0022120860 Pilot Orifi ce (NG) 593-528 Pilot Orifi ce (LP) 593-527 Regulator (NG) Pre 0022120860 NGK-DXV Regulator (LP) Pre 0022120860 LPK-DXV Additional service part numbers appear on following page. Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 66 Post 0022120860 NGK-ESC42ST-B Conversion Kit LP Post 0022120860 LPK-ESC42ST-B Pilot Orifi ce (NG) 593-528 Pilot Orifi ce (LP) 593-527 Regulator (NG) Post 0022120860 NGK-DXV-50 Regulator (LP) Post 0022120860 LPK-DXV-50 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...
  • Page 67: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2014 Heat & Glo • ESC-42ST • 2146-900 Rev. V • 5/14...

Table of Contents