Electrical Section - DeLonghi DSC 90 DF FSD User Operating Instructions Manual

Delonghi dsc 90 df fsd dual fuel cooker
Hide thumbs Also See for DSC 90 DF FSD:
Table of Contents

Advertisement

1
1
The appliance must be connected to the electrical network verifying above all that the
voltage corresponds to the value indicated on the specifications plate and that the
cables section of the electrical plant can bear the load which is also indicated on the
plate.
It is recomended that the appliance is connected directly to the mains by fixed wiring,
placing a double pole switch with minimum opening between the contacts of 3 mm.
lternative connection methods may be available as long as they conform to current
IEE wiring regulation.
The power supply cable must not touch the hot parts and must be positioned so that it
does not exceed 75°C at any point.
Once the cooker has been installed, the switch must always be accessible.
Before effecting any intervention
on the electrical parts the appli-
ance must be disconnected from
the network.
CONNECTING FEEDER
C BLE
To connect the feeder cable to the
cooker it is necessary to:
– Remove the screw that hold shield
" " behind the cooker (fig. 10.1).
– Insert the feeder cable of the suitable
section (as described in the next chap-
ter) into the cable clamp "D".
– Connect the phase and earth cables
to the terminal block "B" according to
the diagram in figure 10.2.
– Pull the feeder cable and block it with
cable clamp "D".
– Re-mount shield " ".
Feeder cable section
type H05RR-F
230 V
38

Electrical section

ELECTRICITY C N BE EXTREMELY D NGEROUS.
THIS PPLI NCE MUST BE E RTHED.
2
3 x 1,5 mm
W RNING!
Fig. 10.1
Fig. 10.2
D
PE
B
A
230 V
L
N
PE
1
(L
)
2

Hide quick links: