Attention
:
1. Never let optical parts come into contact with oil or grease.
2. Before running the fixture wait until all parts are dry.

5.3 Cleaning the Optical System

1. Disconnect the main power supply!
2. Wait at least 20 minutes after the last operation to cool down the fixture.
3. Remove the Rotating Head by loosening the 6 head-screws.
4. Remove the inside optical plug-in by loosening the two hexagon socket screws and
pull it out.
5. Clean all glasses, lenses and mirrors carefully.
6. Before you put the MINI PATEND
your retina can be hurt!
Elation Professionals
MINI PATEND
back into operation close the casing, otherwise
-
wwww.ElationLighting.com