Elation FUZE SFX WH User Manual
Hide thumbs Also See for FUZE SFX WH:

Advertisement

Quick Links

FUZE SFX
FUZE SFX WH
user manual

Advertisement

Table of Contents
loading

Summary of Contents for Elation FUZE SFX WH

  • Page 1 FUZE SFX FUZE SFX WH user manual...
  • Page 2 +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu info@elationlighting.eu Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 (728) 282-7070 DOCUMENT VERSION Due to additional product features and/or enhancements, an updated version of this document may be available online.
  • Page 3: Table Of Contents

    C O N T E N T S General Information Warranty Returns (USA Only) Safety Guidelines Maintenance Guidelines Overview Color Wheel Gobo Wheels Custom Gobos Gobo Installation Installation Guidelines System Menu Software Update Dimmer Mode DMX Channel Functions and Values Color Combination Table Remote Device Management (RDM) Error Codes...
  • Page 4: General Information

    Omega Brackets (x2) Locking Power Cable (X1) CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments or suggestions. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET +31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu...
  • Page 5: Warranty Returns (Usa Only)

    It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States.
  • Page 6: Safety Guidelines

    This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
  • Page 7 S A F E T Y G U I D E L I N E S DO NOT TOUCH the fixture housing during operation. DO NOT shake fixture and avoid brute force when installing and/or operating fixture. DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged or do not fit into the fixture securely with ease.
  • Page 8: Maintenance Guidelines

    Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
  • Page 9: Overview

    O V E R V I E W...
  • Page 10: Color Wheel

    C O LO R W H E E L Slot Number Color Warm Yellow Medium Green Orange Pink Medium Blue...
  • Page 11: Gobo Wheels

    G O B O W H E E L S...
  • Page 12: Custom Gobos

    Extended testing of custom gobo designs is highly recom- mended prior to use. Contact ELATION SERVICE for further information. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com...
  • Page 13: Gobo Installation

    G O B O I N S TA L L AT I O N 1. Place the fixture on a stable flat surface in a DUST-FREE, INDOOR location, and ensure that the unit has been disconnected from power and given at least 15 minutes to cool down after powering down.
  • Page 14 G O B O I N S TA L L AT I O N 3. Optional. This step may be performed to help improve access to the gobo wheel module. On the prism module, find the 4-pin connector (denoted by the yellow box, above right) that is located behind the left-most electric motor, just beside the thumb screw on the left hand side of the prism module.
  • Page 15 G O B O I N S TA L L AT I O N 5. On the gobo wheel module, locate the circuit board on the left-hand side of the gobo wheel module, directly above the static gobo wheel. On this circuit board, find the 3-pin connector and the 4-pin connector (denoted by the yellow boxes, above right) located just behind a bank of three (3) capacitors, and disconnect both of these connectors.
  • Page 16 G O B O I N S TA L L AT I O N 7. Locate the rotating gobo that will be replaced. Grip the edges of the geared gobo holder and gently lift (pictured at left) until the gobo holder clears the surface of the gobo wheel. Then pull the gobo holder out and away (pictured at right).
  • Page 17: Installation Guidelines

    I N S TA L L AT I O N G U I D E L I N E S FLAMMABLE MATERIAL WARNING Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations.
  • Page 18 I N S TA L L AT I O N G U I D E L I N E S OMEGA BRACKETS INSTALLATION Insert the Omega Brackets into the matching holes on the bottom of the fixture. Secure the Omega Brackets to the fixture by turning each quick-lock fastener ¼ turn clockwise; making sure the fastener is completely locked.
  • Page 19 I N S TA L L AT I O N G U I D E L I N E S When installing the unit, the trussing or area of installation must be able to hold 10 times the weight of the fixture without any deformation. When installing, the unit must be secured with a secondary safety attachment, e.g.
  • Page 20 LEDs. This issue is not specific to ELATION lighting fixtures; it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
  • Page 21: System Menu

    ICON button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press. Note: An Elation C-Loader II can be used to update fixture software. Contact Elation Service for more information @ 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com...
  • Page 22 S YS T E M M E N U OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD) DMX Address A001 - A512 Hold Last DMX Settings No DMX Status Blackout Internal Programs Primary On / Off Secondary On / Off Pan Invert...
  • Page 23 S YS T E M M E N U OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD) 900Hz – 1500Hz (default 1200Hz) 2500 Hz 4000 Hz 5000 Hz LED Refresh Rate 6000 Hz 10 KHz 15 KHz 20 KHz 25 KHz E-FLY...
  • Page 24 S YS T E M M E N U OPTIONS / VALUES MAIN MENU SUB MENU DESCRIPTION (Default Settings in BOLD) Focus Rot. Gobo 7 Focus Rot. Gobo 8 Focus Fix Gobo 1 Focus Fix Gobo 2 Focus Fix Gobo 3 Focus Fix Gobo 4 Calibration Focus Fix Gobo 5...
  • Page 25: Software Update

    S O F T WA R E U P D AT E Software Update Via USB for Single-Fixture or Multiple Linked Fixtures. Contact Elation Service for updated software: @323-582-3322 | Fax 323-832-9142 | support@elationlighting.com Copy the latest software to a USB Flash Drive. With the software loaded on the USB Flash Drive, insert it into the USB Service Port.
  • Page 26 S O F T WA R E U P D AT E Software Update Via USB for Single-Fixture Only. Contact Elation Service for updated software: @323-582-3322 | Fax 323-832-9142 | support@elationlighting.com Copy the latest software to a USB Flash Drive. Ensure the fixture is turned off. With the fixture powered off, insert the USB Flash Drive into the USB Service Port, then power the fixture on.
  • Page 27: Dimmer Mode

    D I M M E R M O D E...
  • Page 28: Dmx Channel Functions And Values

    D MX TR AI TS: C HANN EL F UNCT IONS AND VALU ES CHANNEL VALUE FUNCTION 000 – 255 Pan Movement 000 – 255 Pan Movement Fine 000 – 255 Tilt Movement 000 – 255 Tilt Movement Fine Cyan Full 000 –...
  • Page 29 D MX TR AI TS: C HANN EL F UNCT IONS AND VALU ES CHANNEL VALUE FUNCTION Color Wheel 000 – 005 Open 006 – 010 White/Red Split 011 – 015 016 – 020 Red/Yellow Split 021 – 025 Yellow 026 –...
  • Page 30 D MX TR AI TS: C HANN EL F UNCT IONS AND VALU ES CHANNEL VALUE FUNCTION Rotating Gobo 000 – 005 Open 006 – 012 Rotating Gobo 1 013 – 019 Rotating Gobo 2 020 – 026 Rotating Gobo 3 027 –...
  • Page 31 D MX TR AI TS: C HANN EL F UNCT IONS AND VALU E S CHANNEL VALUE FUNCTION DEFAULT SNAP HOLD 000 – 020 Open 021 – 040 Prism 1 041 – 060 Prism 2 061 – 080 Prism 1 + 2 081 –...
  • Page 32 D M X T R AITS: C HANNE L F UNCT IONS AND VALU E S CHANNEL VALUE FUNCTION Dimmer Configuration Dim Modes 000 – 020 Standard 021 – 040 Stage 041 – 060 061 – 080 Architectural 081 – 100 Theatre 101 –...
  • Page 33 D M X T R AI TS: CH ANNE L F UNCT IONS AND VALU E S CHANNEL VALUE FUNCTION CONTROL 000 – 009 Color Change Normal 010 – 019 Color Change to Any Position 020 – 029 Color & Gobo Change to Any Position 030 –...
  • Page 34 D MX TR AI TS: C HANN EL F UNCT IONS AND VALU E S CHANNEL VALUE FUNCTION 1110 Hz 1120 Hz 1130 Hz 1140 Hz 1150 Hz 1160 Hz 1170 Hz 1180 Hz 1190 Hz 1200 Hz 1210 Hz 1220 Hz 1230 Hz 1240 Hz...
  • Page 35 D M X T R AITS: CHA NNE L FUNCTIONS A ND VALU E S CHANNEL VALUE FUNCTION 2500 Hz 4000 Hz 5000 Hz 6000 Hz 10000 Hz 15000 Hz 20000 Hz 25000 Hz 169 – 190 Idle 191 – 195 Hibernation OFF 196 –...
  • Page 36: Color Combination Table

    C O L O R C O M B I N AT I O N TA B L E COLOR COMBINATIONS COMBINATION IMAGE CYAN MAGENTA YELLOW COLOR WHEEL 50% split 50% split Open 100% 50% split Open 100% split Open 33% split 33% split Open...
  • Page 37: Remote Device Management (Rdm)

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
  • Page 38: Error Codes

    E R R O R C O D E S Error Codes subject to change without notice ERROR CODES DESCRIPTION Movement is not located in the default position after the reset. These messages will appear after a fixture reset if the magnetic-indexing PAN Er circuit malfunctions (sensor failed, or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the...
  • Page 39: Specifications

    S P E C I F I C AT I O N S SOURCE 300W 6,600K Bright White LED Engine 20,000 Hour Average LED Life* *Test lab conditions. May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming. PHOTOMETRIC DATA 12,135 Total Lumen Output CRI 68+...
  • Page 40: Dimensional Drawings

    D I M E N S I O N S *Drawings not to scale. Specifications and improvements in the design of this unit and this manual are subject to change without notice.
  • Page 41: Fcc Statement

    F C C S TAT E M E N T This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This manual is also suitable for:

Fuze sfxFuz406

Table of Contents