Regency ULTIMATE U39 Owners & Installation Manual page 13

Regency ultimate u39 freestanding gas stove
Hide thumbs Also See for ULTIMATE U39:
Table of Contents

Advertisement

Description
Attic Insulation Shield 12"
Attic Insulation Shield -
36"
Cold Climates
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA only)
Chimney Conversion Kit Masonry
(USA only)
Wall Firestop
Colinear Flex Connectors
FPI
946-506/P
Vent Guard (Optional) for AstroCap
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
946-605
Starter Collar Increaser 4" x 6-5/8" to 5" x 8"
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
4" x 6-5/8" Venting
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com
Selkirk
Simpson
Direct Temp™
Direct Vent Pro
®
46DVA-IS
N/A
N/A@ FPI
N/A
N/A
Disc.
4DT-HKA
46DVA-KHA
4DT-HKB
(Changed Components)
Disc.
4DT-VKC
46DVA-VCH
N/A
46DVA-HC
N/A
See 46DVA-HC
4DT-HHC
46DVA-VC
4DT-HVC
46DVA-08A
4DT-SC
46DVA-F6
4DT-ST14
46DVA-FLA
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNKL
N/A
N/A
N/A
N/A
N/A
N/A
N/A
46DVA-KCA
N/A
46DVA-KCB
N/A
46DVA-KCC
N/A
46DVA-KMC
N/A
46DVA-WFS
N/A
46DVA-ADF
N/A
946-205
946-208/P
946-523/P
946-206
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
American Metal
Metal-Fab™
Products®
Sure Seal
Amerivent Direct
4DAIS12
N/A
4DAIS12
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DHC
4DHT
4DVC
4DVT
4DSC
4DSC
4D12S
4DST14
4D36S
4DST36
N/A
4DVS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Vinyl Siding Shield for Riser Vent Terminal
Vent Guard (Optional) for Riser Vent Terminal
AstroCap Horizontal Cap
Vinyl Siding Standoff for AstroCap
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Regency
U39-10 ULTIMATE Direct Vent Freestanding Gas Stove
®
installation
Security
ICC Excel
Secure- Vent®
Direct
SV4RSA
N/A
N/A
TM-4AS
SV-SHK
TM4-HTK
SV-HK
TM4-HTK
SV-FK
N/A
N/A
TM-4VT
N/A
TM-4DHT
SV4CHC-1
TM-4HT
SV4CGV-1
N/A
SV4FC
TM-SC
SV4STC14
TF-4FA
SV4STC36
TF-4FB
SV4VS
TM-VSS
SV4VS
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4DS
N/A
N/A
N/A
TM-4CA6
N/A
TM-4CA7
N/A
TM-4CA8
N/A
N/A
N/A
TM-4TR
N/A
N/A
|
13
|
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39-ng10Ultimate u39-lp10

Table of Contents