Adjusting The Pressure Of The Separation Roller Of The Manual Feed Tray - Canon iR5000i Service Manual

Hide thumbs Also See for iR5000i:
Table of Contents

Advertisement

CHAPTER 3 STANDARDS AND ADJUSTMENTS
4.7 Adjusting the Pressure of the Separation Roller of the
Manual Feed Tray
If double feeding or pickup failure occurs during pickup, adjust the position of the pres-
sure spring of the separation roller.
1) Remove the right upper cover.
2) Remove the upper guide [1].
If double feeding occurs, remove the mounting screw [2], and lower the mounting base
[3]; then, tighten the mounting screw [2] in hole A.
If pickup failure occurs, remove the mounting screw [2], and raise the mounting base
[3]; then, tighten the mounting screw [2] in hole B.
3-14 T
F03-407-01
hole A
hole B
F03-407-02
COPYRIGHT © 2001 CANON INC.
[1]
[2]
[3]
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001