Canon iR5000i Service Manual page 144

Hide thumbs Also See for iR5000i:
Table of Contents

Advertisement

CHAPTER 2 ORIGINAL EXPOSURE SYSTEM
2) Insert the pins of the mirror positioning
tool (front [2]/rear [3]) into each of the
holes [1]: No. 1 mirror base, No. 2 mir-
ror base, and rail. The position of the
No. 2 mirror base is adjusted by sliding
the cable fixing plate to the front and
the rear.
3) Secure the end of the cable so far tem-
porarily fixed to the hook of the reader
frame using a spring.
4) Fully tighten the screw on the cable fix-
ing plate.
5) Fully tighten the cable metal fixing on
the No. 1 mirror base.
6) Detach the mirror positioning tool.
7) Reverse steps 1) through 6) for mount-
ing.
2-24 R
COPYRIGHT © 2001 CANON INC.
F02-602-08
[3]
F02-602-09
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[2]
[1]
[1]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir6000iImage reader-a1

Table of Contents