Https Browser Port; Rcp+ Port 1756; Telnet Support; Interface Mode Eth - Bosch FLEXIDOME corner 9000 MP Software Manual

Camera bosch flexidome corner 9000 mp
Table of Contents

Advertisement

92
en | Network
14.1.8

HTTPS browser port

To limit browser access to encrypted connections, choose an
HTTPS port from the list. The standard HTTPS port is 443.
Select the Off option to deactivate HTTPS ports and limit
connections to unencrypted ports.
The camera uses the TLS 1.0 protocol. Ensure that the browser
has been configured to support this protocol. Also ensure that
Java application support is activated (in the Java Plug-in
Control Panel of the Windows Control Panel).
To limit connections to SSL encryption, set the Off option in
the HTTP browser port, the RCP+ port, and Telnet support. This
deactivates all unencrypted connections allowing connections
on the HTTPS port only.
Configure and activate encryption for media data (video, audio,
metadata) on the Encryption page.
14.1.9

RCP+ port 1756

Activating RCP+ port 1756 allows unencrypted connections on
this port. To allow only encrypted connections, set the Off
option to deactivate the port.
14.1.10

Telnet support

Activating Telenet support allows unencrypted connections on
this port. To allow only encrypted connections, set the Off
option to deactivate telnet support, making telnet connections
impossible.
14.1.11

Interface mode ETH

If necessary, select the Ethernet link type for interface ETH.
Depending on the network equipment connected (for example,
a switch), it may be necessary to select a special operation
type.
14.1.12

Network MSS [Byte]

Set the maximum segment size for the IP packet's user data
here. This gives the option to adjust the size of the data packets
to the network environment and to optimize data transmission.
In UDP mode, comply with the MTU value set below.
AM18-Q0649 | v5.8 | 2013.06