Camera Browser Interface
13

Interfaces

13.1

Alarm input

Configure the alarm triggers for the camera.
Select N.C. (Normally Closed) if the alarm is to be triggered by
closing the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by
opening the contact.
13.1.1

Name

Enter a name for the alarm input. This is then displayed below
the icon for the alarm input on the LIVEPAGE (if configured).
13.2

Alarm Output

Configure the switching behavior of the alarm output.
Select different events that automatically activate an output.
For example, turn on a floodlight by triggering a motion alarm
and then turn the light off again when the alarm has stopped.
13.2.1

Idle state

Select Open for the output to operate as an N.O. contact, or
select Closed if the output is to operate as an N.C. contact.
13.2.2

Operating mode

Select the way the output works.
13.2.3

Output follows

Select the event that triggers the output.
13.2.4

Output name

The output can be assigned a name here. The name is shown on
the button next to Trigger output. The LIVEPAGE can also be
configured to display the name next to the output icon.
13.2.5

Trigger output

Click the button to switch the output manually (for example, for
testing purposes or to operate a door opener).