INSTALLATION REQUIREMENTS

General

We recommend that the product be brought into the room where it is to be installed
and left to acclimatise to room temperature, this will reduce the possibility of
condensation on electronic components.
The shower works best when water supply conditions are stable and within the
specifications, refer to section 'Specifications'. If the supply conditions fall outside
the specifications, the shower may go into a safe shut down condition.
If pipework and/or electrical cables enter the shower from the rear through a hole in
the wall, provision must be made to prevent water ingress back into the wall structure.
Route cable and pipe supplies via the cut outs moulded in the case and cover.
DO NOT increase the size or cut alternative pipe / cable entry points as water ingress
into the product may occur.

1. Plumbing

Refer to section: 'Important Safety Information' first.
1.1 Do not use sealing compounds on any pipe fittings or joints.
1.2 To avoid damage to the case when soldered fittings are used, pre-solder the
pipework and fittings before connecting them to the inlet connector assembly.
1.3 Never fit the appliance to hot water supplies or to gravity systems of any
description. Only fit the product to a mains cold water pipe.
184 mm
9
102 mm
71 mm
Advance ATL Flex / Flex Extra /
Flex Extra Wireless
184 mm