Toshiba MMD-AP0071SH-C Service Manual page 48

Table of Contents

Advertisement

11
TROUBLESHOOTING
Check code
Wireless remote controller
Sensor block display
Main
Outdoor 7-segment display
AI-NET central
remote
controller
control display
display
Auxiliary code
Operation
¤
F01
0F
¤
F02
0d
¤
F03
93
¤
F04
F04
19
¤
F05
F05
A1
¤
F06
F06
18
¤
F07
F07
18
¤
F08
F08
1b
¤
F10
OC
¤
F12
F12
A2
01: Comp. 1 side
¤
F13
F13
43
02: Comp. 2 side
¤
F15
F15
18
¤
F16
F16
43
¤
F23
F23
43
¤
F24
F24
43
¤
F29
12
¤
F31
F31
1C
l
01: Comp. 1 side
H01
H01
IF
02: Comp. 2 side
01: Comp. 1 side
l
H02
H02
1d
02: Comp. 2 side
01: Comp. 1 side
l
H03
H03
17
02: Comp. 2 side
l
H04
H04
44
l
H06
H06
20
l
H07
H07
d7
01: TK1 sensor error
l
02: TK2 sensor error
d4
H08
H08
03: TK3 sensor error
04: TK4 sensor error
l
H14
H14
44
01: TK1 oil circuit system error
02: TK2 oil circuit system error
l
H16
H16
d7
03: TK3 oil circuit system error
04: TK4 oil circuit system error
¤
L03
96
¤
L04
L04
96
¤
L05
96
¤
L06
L06
No. of indoor units with priority
96
¤
L07
99
¤
L08
L08
99
¤
L09
46
¤
L10
L10
88
¤
L20
L20
98
¤
L28
L28
46
01: IPDU1 error
02: IPDU2 error
03: IPDU3 error
¤
L29
L29
04: Fan IPDU error
CF
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
¤
L30
L30
Detected indoor address
b6
L31
Check code name
Judging device
of receiving unit
Timer Ready Flash
l
¤
ALT
Indoor TCJ sensor error
l
¤
ALT
Indoor TC2 sensor error
l
¤
ALT
Indoor TC1 sensor error
¤
¡
ALT
TD1 sensor error
¤
¡
ALT
TD2 sensor error
¡
¤
ALT
TE1 sensor error
¤
¡
ALT
TL sensor error
¡
¤
ALT
TO sensor error
l
¤
ALT
Indoor TA sensor error
¡
¤
ALT
TS1 sensor error
¡
¤
ALT
TH sensor error
¤
¡
ALT
Outdoor temp. sensor miscabling (TE, TL)
¤
¡
ALT
Outdoor pressure sensor miscabling (Pd, Ps)
¡
¤
ALT
Ps sensor error
¤
¡
ALT
Pd sensor error
l
¤
SIM
Indoor other error
¤
¡
SIM
Indoor EEPROM error
l
¤
Compressor break down
Magnet switch error
l
¤
Overcurrent relay operation
Overcurrent relay
Compressor trouble (lock)
l
¤
Current detect circuit system error
l
¤
Comp 1 case thermo operation
l
¤
Low pressure protective operation
l
¤
Oil level down detective protection
l
¤
Oil level detective temp sensor error
l
¤
Comp 2 case thermo operation
Oil level detective circuit error
l
¤
Magnet switch error
Overcurrent relay operation
Overcurrent relay
l
¤
SIM
Indoor center unit duplicated
¡
¤
SIM
Outdoor line address duplicated
l
Duplicated indoor units with priority
¤
SIM
(Displayed in indoor unit with priority)
Duplicated indoor units with priority
l
¤
SIM
(Displayed in unit other than indoor unit with
priority)
l
¤
SIM
Group line in individual indoor unit
l
¤
SIM
Indoor group/Address unset
l
¤
SIM
Indoor capacity unset
¡
¤
SIM
Outdoor capacity unset
¡
¤
SIM
Duplicated central control addresses
AI-NET, Indoor
¡
¤
SIM
Over No. of connected outdoor units
¡
¤
SIM
No. of IPDU error
¡
¤
SIM
Indoor outside interlock
Extended I/C error
Check code
Main
Outdoor 7-segment display
remote
controller
display
Auxiliary code
Indoor
P01
Indoor
P03
P03
Indoor
01: Comp. 1 side
P04
P04
02: Comp. 2 side
I/F
01: Phase-missing detection
P05
P05
I/F
02: Phase error
I/F
01: Comp. 1 side
P07
P07
02: Comp. 2 side
I/F
P10
P10
Detected indoor address
I/F
P12
Indoor
P13
P13
I/F
01: TS condition
P15
P15
IPDU
02: TD condition
P17
P17
I/F
P19
P19
Detected outdoor unit number
I/F
P20
P20
I/F
0
: IGBT short
I/F
1
: Fan motor position
detective circuit error
Indoor
3
: Fan motor trouble
P22
P22
C
: TH sensor temp. error
I/F
(Heat sink overheat)
D
: TH sensor error
IPDU
E
: Vdc output error
MG-SW
01: Comp. 1 side
P26
P26
02: Comp. 2 side
IPDU
01: Comp. 1 side
P29
P29
02: Comp. 2 side
IPDU
P31
P31
I/F
I/F
I/F
I/F
I/F
I/F
Error detected by TCC-LINK central control device
MG-SW
Check code
Indoor
Central
Outdoor 7-segment display
control
I/F
device
indication
Auxiliary code
I/F
C05
I/F
C06
Indoor
C12
Indoor, I/F
Differs according to error contents of unit with occurrence of alarm
Indoor
P30
I/F
I/F
Terminology
I/F
TCC-LINK : TOSHIBA Carriea Cominication Link.
Indoor
I/F
Wireless remote controller
Sensor block display
Check code name
AI-NET central
of receiving unit
control display
Operation
Timer Ready Flash
l
¤
¤
11
ALT
Indoor fan motor error
l
¤
¤
1E
ALT
Discharge temp. TD1 error
l
¤
¤
21
ALT
High-pressure SW system operation
l
¤
¤
AF
ALT
Phase-missing detection /Phase error
l
¤
¤
IC
ALT
Heat sink overheat error
l
¤
¤
Ob
ALT
Indoor overflow error
l
¤
¤
11
ALT
Indoor fan motor error
l
¤
¤
47
ALT
Outdoor liquid back detection error
l
¤
¤
AE
ALT
Gas leak detection
l
¤
¤
bb
ALT
Discharge temp. TD2 error
l
¤
¤
O8
ALT
4-way valve inverse error
l
¤
¤
22
ALT
High-pressure protective operation
l
¤
¤
1A
ALT
Outdoor fan IPDU error
l
¤
¤
14
ALT
G-TR short protection error
l
¤
¤
16
ALT
Comp position detective circuit system error
l
Other indoor unit error
¤
¤
47
ALT
(Group terminal unit error)
b7
By alarm device
ALT
Error in indoor group
97
AI-NET communication system error
99
Duplicated network adaptors
Wireless remote controller
Sensor block display
Check code name
AI-NET central
of receiving unit
control display
Operation
Timer Ready Flash
Sending error in TCC-LINK central
control device
Receiving error in TCC-LINK central
control device
Batch alarm of general-purpose
equipment control interface
Group control branching unit error
(L20 is displayed.)
Duplicated central control addresses
Judging device
Indoor
I/F
IPDU
I/F
IPDU, I/F
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
IPDU
IPDU
IPDU
Indoor
AI-NET
AI-NET
AI-NET
Judging device
TCC-LINK
TCC-LINK
General-purpose equipment
I/F
TCC-LINK