No.
Part name
Fan motor
1. Detachment
1) Perform works 1. of
2) Remove lead wires which are connected to the
NOTE) Unlock locks of the housing, and then remove
3) Remove the noise filter from lead wire to detect
4) Take off screws of fan motor fixing bracket.
5) Remove fixing bracket of the fan motor by holding
2. Attachment
1) Mount the fan motor as before in order, Fan motor → Fixing bracket of fan motor →
NOTE) Check there is no missing or poor contact of the connectors.
ˆ
Under panel
1. Detachment
Drain pan
1) Take off the drain cap and drain the drain water
assembly
NOTE) When taking off drain cap and drain hose, be
2) Take off screws fixing the under panel while
NOTE) Be careful that sheeting metal does not fall
3) Pull out the drain pan assy. by holding handle at
NOTE) When pulling out the drain pan assy., never pull
4) Pull out it to some extent, lay hand on the bump at
2. Attachment
1) Hook and attach the drain pan assy. to the flange
2) Using screws taken off in procedure 1. 2) of
3) Attach drain cap, hose band, and drain hose as
NOTE) Finally, be sure to check there is no water
Procedure
, 1. of
following connectors of P .C. board assembly.
the connectors.
CN333: Fan motor power supply (5P: White)
CN334: Detection of fan motor (5P: White)
Remove tie wrap which fixes lead wires.
fan motor position.
Earth wires of the motor are tightened together.
(Ø5 × 10, 2 pcs)
Remove tie wrap which fixes the lead wires.
it with hands so that the fan motor does not fall
down.
Noise filter → Lead wire process → E-cover.
Check also that the multi blade fan turns surely and smoothly, and check together-
tightening of motor earth.
accumulated in the drain pan assembly.
In case of natural drain model, drain the drain
water by taking off hose band and drain hose.
sure receive drain water in a bucket, etc.
holding it to remove. (Ø4 × 10, 8 pcs)
when removing the under panel.
lower part.
out the drain socket by drawing it with hands. If
doing so, water leak may be caused.
suction side, and then remove the drain pan
assembly.
at discharge side, and then push in.
attach under panel by holding with hands.
before, which were taken off in procedure 1. 1) of
ˆ
.
leakage from each attached part.
ƒ
, 1. of
.
ˆ
,
121
Remarks
Noise filter
Ear th lead
th lead
Ear
Earth lead
Drain cap or drain hose
Under panel
Under panel
Under panel
Dr ain pan assemb
ain pan assemb ly
Drain pan assembly
Dr
NO GOOD
Never hold and pull
the drain socket.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents