Samsung NX-828 Technical Manual page 124

Hybrid key system electronic key/hybrid telephone system
Hide thumbs Also See for NX-828:
Table of Contents

Advertisement

NX-828
HYBRID KEY SYSTEM
MMC 50
Description:
Used to adjust individual timers as necessary. All available timers are described
in the Table of Timers and Values, below.
NOTE: Display shows second as S, millisecond as MS, and minute as MI.
Action
1.
Press AUTO RDL and dial 50
2.
Press LINE1 or LINE2 to select timer
(e.g. ALM R DUR)
3.
Enter new value using KEYPAD(e.g. 005)
4.
Press AUTO RDL to save and exit
DEFAULT DATA
Se e TABL E OF TIMER S AN D VAL U ES
RELATED MMC
NONE
DISPLAY
ALM R INT
(Alarm ring interval)
ALM R DUR
(Alarm ring duration)
ARDL INT
(Auto Redial interval)
ARDL RELS
(Auto Redial release time)
CBACK NOA
(Callback no answer time)
CO CO DIS
(CO to CO disconnect time)
DISA FDG
DISA IDG
DISA RING
DOOR RELS
(Door release time)
DOR R OFF
(Door Ring OFF duration)
TABLE OF TIMERS AND VALUES
DESCRIPTION
Controls the time between ring attempts at a station when alarm
reminder is set.
Controls the length of ring cycle duration when alarm reminder is set
at a station.
Controls the time between attempts after Auto Redial is set on a
station.
Controls the duration of a Ring No Answer condition on an auto redial
number dialled before auto redial is automatically cancelled.
Controls the time before the callback is automatically cancelled when a
callback detects Ring No Answer.
Monitors the duration of an unsupervised conference, external call;
forward or DISA call upon expiring, both trunks are disconnected.
First digit want time in DISA call
Inter digit duration in DISA call
Controls the duration of ringing at the DISA called station before
automatically
transferred to the operator group.
Controls the duration of time before the door lock relay is activated.
Controls the duration of ringing at the door ring destination before
automatically cancelling.
SYSTEM TIMERS
Display
ALM R INT :025SEC
ALM R DUR: 010SEC
ALM R DUR: 005SEC
PROGRAMMING
DEFAULT
RANGE
025S
1-250S
010S
1-250S
045S
1-250S
045S
1-250MI
030S
100-2500MS
010MI
1-250S
025S
1-250S
025S
1-250S
030s
1-250S
1500MS
100-2500MS
030S
1-250S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents