2.1 Construction and function of the collectors
Vitosol 100
Flat collectors
Flat collectors are mainly used for
domestic hot water and swimming pool
heating applications.
Vitosol 100
H Type s/w 2.5
A Continuous profiled seal (vulcanised)
B Solar glass cover, 4 mm thick
C Meander−shaped copper pipe
D Copper absorber
E Melamine resin foam
H Type 5 DI
A Solar glass cover, 4 mm thick
B Aluminium cover frame
C Copper harp absorber
D Reinforcement frame
E Mineral fibre insulating strip
10
F Mineral fibre
G Aluminium frame sections
H Aluminium−zinc bottom plate
K Connection pipe
F Mineral fibre insulating mat
G Aluminium housing
H Flexible connection pipe with
thermal insulation
K Installation hook
The main component of Vitosol 100 is the
A
Sol titanium coated copper absorber.
B
It ensures high absorption of solar
radiation and low emission of thermal
C
radiation. A copper pipe through which
D
the process medium flows is fitted to the
absorber. The process medium channels
the absorber heat through the copper
E
pipe.
The meander−shaped direct flow absorber
F
of type s/w 2.5 provides an extremely
G
even flow through each individual
collector in the collector arrays.
H
The absorber is encased in a highly
insulated collector housing, which
minimises collector heat losses. The high
quality thermal insulation provides
temperature stability and is free from gas
emissions.
The cover comprises a solar glass panel.
The glass has a very low iron content,
thereby reducing reflection losses.
The collector housing comprises an
aluminium frame (recycled aluminium),
powder−coated for model type s/w 2.5,
natural finish for type 5 DI, within which
the solar glass panel is permanently
sealed.
Type s/w 2.5
Up to ten collectors can be joined to form
a single collector array.
For this purpose, the standard delivery
includes flexible connection pipes,
which are sealed with O−rings.
A connection kit with clamping ring
fittings enables the collector array to be
quickly connected to the pipes of the
solar circuit.
A
A collector temperature sensor is
installed via a sensor well set into the
B
solar circuit flow.
C
Type 5 DI
At the back of the collector are flexible,
D
thermally insulated flow and return pipes,
E
as well as the sensor well for the collector
temperature sensor.
F
G
H
K
VITOSOL