Periodic Maintenance Procedures - Kyocera Mita KM-2530 Service Manual

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

2DF

Periodic maintenance procedures

Maintenance
Section
part/location
Test copy and
Perform at the maximum
test print
copy size
Maintenance
Section
part/location
Paper feed
Upper/lower paper feed
section
pulley
Upper/lower separation
pulley
Upper/lower forwarding
pulley
Bypass paper feed pulley
Bypass separation pulley
Bypass forwarding pulley
Bypass feed roller 1
Bypass feed roller 2
Left registration roller
Right registration roller
Feed pulley
Feed roller 1
Feed roller 2
Feed roller 3
Registration switch
Maintenance
Section
part/location
Optical section
Slit glass
Contact glass
Mirror 1
Mirror 2 and mirror 3
Lens
Reflector
Exposure lamp
Optical rail
Original size detection
sensor
2-4-16
Method
Maintenance cycle
Test copy
Every service
Method
Maintenance cycle
Replace
Every service
Replace
Every service
Replace
Every service
Replace
Every service
Replace
Every service
Replace
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Method
Maintenance cycle
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean
Every service
Clean or replace
Every service
Grease
Every service
Clean
Every service
Points and cautions
Points and cautions
Replace.
Replace.
Replace.
Replace.
Replace.
Replace.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Clean with a dry cloth.
Points and cautions
Clean with alcohol and then
a dry cloth.
Clean with alcohol and then
a dry cloth.
Clean with alcohol and then
a dry cloth only if vertical black
lines appear on the copy image.
Clean with alcohol and then
a dry cloth only if vertical black
lines appear on the copy image.
Clean with a dry cloth only if
vertical black lines appear on
the copy image.
Clean with a dry cloth only if
vertical black lines appear on
the copy image.
Replace if an image problem
occurs.
Check noise and shifting and
then apply scanner rail grease
PG671.
Clean the sensor emitter and
receiver with alcohol or a dry
cloth only if there is a problem.
Page
Page
1-6-3
1-6-3
1-6-3
1-6-5
1-6-5
1-6-5