Detaching And Refitting The Fixing Unit Thermistor - Kyocera Mita KM-2530 Service Manual

Hide thumbs Also See for KM-2530:
Table of Contents

Advertisement

2DF

(6) Detaching and refitting the fixing unit thermistor

Follow the procedure below to replace the fixing unit thermistor.
Procedure
1. Remove the fixing unit (see page 1-6-36).
2. Remove the upper fixing cover (see page 1-
6-36).
3. Disconnect the connector of the fixing unit
thermistor.
4. Remove the heat roller (see page 1-6-39).
5. Turn the fixing unit over and remove the
screw to remove the fixing unit thermistor.
1-6-40
Connector
Figure 1-6-76
Fixing unit thermistor
Figure 1-6-77