Indoor Unit
1.7

Removal of Swing Motor / PCBs

Procedure
Step
1. Remove the shield plate
(2).
1
Unfasten the hooks at
the upper 2 positions of
the shield plate (2).
Unfasten the hook at
2
the lower position,
and remove the shield
plate (2).
2. Remove the swing motor.
1
Remove the screw of
the swing motor.
122
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Electrical box
Hook
Preparation
Shield plate (2)
(R14603)
Hook
(R16650)
Swing motor
(R11650)
SiBE041134
Points
Remove the electrical box
according to the "Removal
of Electrical Box".