Daikin FTXS20K2V1B Service Manual page 106

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXS20K2V1B:
Table of Contents

Advertisement

Troubleshooting
Troubleshooting
Check No.17
Refer to P.107
Check No.19
Refer to P.108
96
Be sure to turn off the power switch before connecting or disconnecting
Be sure to turn off the power switch before connecting or disconnecting
Caution
Caution
connectors, or parts may be damaged.
connectors, or parts may be damaged.
Turn off the power and turn it on
Turn off the power and turn it on
again.
again.
Error again or outdoor
Error again or outdoor
fan activated?
fan activated?
NO
NO
Check No. 19
Check No. 09
Check the outdoor fan or
Check the outdoor fan or
related.
related.
OK
OK
Radiation fin dirty?
Radiation fin dirty?
Slightly dirty
Slightly dirty
Check No. 07
Check No. 17
Check the installation condition.
Check the installation condition.
A (°C)
B (°C)
98
75
YES
YES
Check the radiation fin
Check the radiation fin
temperature.
temperature.
Above
Above
A ˚C?
A ˚C?
YES
YES
NG
NG
Too dirty
Too dirty
C (°C)
83
WARNING
WARNING
To cool the electrical components,
To cool the electrical components,
the outdoor fan starts when the
the outdoor fan starts when the
radiation fin temperature rises
radiation fin temperature rises
above C ˚C and stops when it
above C ˚C and stops when it
drops below B ˚C.
drops below B ˚C.
NO
NO
Replace the outdoor unit
Replace the outdoor unit
PCB.
PCB.
Replace the outdoor fan
Replace the fan motor.
motor.
Correct the connectors and
Correct the connectors
fan motor lead wire.
Replace the outdoor unit
and fan motor lead wire.
PCB.
Replace the outdoor unit
PCB.
Clean up the radiation fin.
Clean up the radiation fin.
Service Diagnosis
SiBE041134
(R14444)