Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
RXS20K2V1B
Daikin RXS20K2V1B Manuals
Manuals and User Guides for Daikin RXS20K2V1B. We have
4
Daikin RXS20K2V1B manuals available for free PDF download: Service Manual, Installation Manual
Daikin RXS20K2V1B Service Manual (184 pages)
Inverter Pair Wall Mounted Type K-Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 6.93 MB
Table of Contents
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
11
Functions
12
Part 2 Specifications
13
Specifications
14
Part 3 Printed Circuit Board Connector Wiring Diagram
15
Indoor Unit
16
Outdoor Unit
18
Part 4 Function and Control
20
Main Functions
21
Temperature Control
21
Frequency Principle
21
Airflow Direction Control
23
Fan Speed Control for Indoor Unit
24
Program Dry Operation
25
Automatic Operation
26
Thermostat Control
27
NIGHT SET Mode
28
ECONO Operation
29
INTELLIGENT EYE Operation
30
Inverter POWERFUL Operation
31
Other Functions
32
Function of Thermistor
33
Control Specification
34
Mode Hierarchy
34
Frequency Control
35
Controls at Mode Changing / Start-Up
37
Discharge Pipe Temperature Control
38
Input Current Control
39
Freeze-Up Protection Control
40
Heating Peak-Cut Control
40
Outdoor Fan Control
41
Liquid Compression Protection Function
41
Defrost Control
42
Electronic Expansion Valve Control
43
Pressure Equalizing Control
44
Malfunctions
46
Part 5 Operation Manual
47
System Configuration
48
Operation Manual
49
Remote Controller
49
Quiet Button
50
Clock Button
50
AUTO · DRY · COOL · HEAT · FAN Operation
51
Operating Conditions
52
Adjusting the Airflow Direction and Rate
53
COMFORT AIRFLOW Operation
55
INTELLIGENT EYE Operation
56
POWERFUL Operation
58
OUTDOOR UNIT QUIET Operation
59
ECONO Operation
60
OFF TIMER Operation
61
ON TIMER Operation
62
WEEKLY TIMER Operation
63
Copy Mode
66
Part 6 Service Diagnosis
69
Troubleshooting with LED
70
Indoor Unit
70
Outdoor Unit
70
Problem Symptoms and Measures
71
Service Check Function
72
Troubleshooting
75
Error Codes and Description
75
Indoor Unit PCB Abnormality
76
Freeze-Up Protection Control or Heating Peak-Cut Control
78
Fan Motor (DC Motor) or Related Abnormality
80
Thermistor or Related Abnormality (Indoor Unit)
82
Refrigerant Shortage
83
Low-Voltage Detection or Over-Voltage Detection
85
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
87
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
89
Outdoor Unit PCB Abnormality
90
OL Activation (Compressor Overload)
91
Compressor Lock
92
DC Fan Lock
93
Input Overcurrent Detection
94
Four Way Valve Abnormality
95
Discharge Pipe Temperature Control
97
High Pressure Control in Cooling
98
Compressor System Sensor Abnormality
99
Position Sensor Abnormality
100
DC Voltage / Current Sensor Abnormality
102
Thermistor or Related Abnormality (Outdoor Unit)
103
Electrical Box Temperature Rise
105
Radiation Fin Temperature Rise
107
Output Overcurrent Detection
109
Check
111
Thermistor Resistance Check
111
Fan Motor Connector Output Check
112
Power Supply Waveforms Check
112
Electronic Expansion Valve Check
113
Four Way Valve Performance Check
114
Inverter Units Refrigerant System Check
114
Inverter Checker" Check
115
Rotation Pulse Check on the Outdoor Unit PCB
116
Installation Condition Check
117
Discharge Pressure Check
117
Outdoor Fan System Check
118
Main Circuit Short Check
118
Power Module Check
119
Part 7 Removal Procedure
120
Indoor Unit
121
Removal of Air Filters
121
Removal of Horizontal Blade
123
Removal of Front Panel
125
Removal of Front Grille
126
Removal of Vertical Blade Assys
127
Removal of Electrical Box
129
Removal of Swing Motor / Pcbs
132
Removal of Indoor Heat Exchanger
137
Removal of Fan Rotor / Fan Motor
140
Exchange of Piping Direction (Drain Hose)
143
Outdoor Unit
144
Removal of Outer Panels / Fan Motor
144
Removal of Electrical Box
153
Removal of Pcbs
156
Removal of Reactor / Partition Plate
164
Removal of Sound Blankets
166
Removal of Four Way Valve
168
Removal of Compressor
171
Part 8 Trial Operation and Field Settings
173
Pump down Operation
174
Forced Cooling Operation
175
Trial Operation
176
Field Settings
177
Model Type Setting
177
When 2 Units Are Installed in 1 Room
177
Standby Electricity Saving
178
Facility Setting Jumper (Cooling at Low Outdoor Temperature)
178
Jumper Settings
179
Application of Silicon Grease to a Power Transistor and a Diode Bridge
180
Part 9 Appendix
181
Piping Diagrams
182
Indoor Unit
182
Outdoor Unit
182
Wiring Diagrams
183
Indoor Unit
183
Outdoor Unit
183
Advertisement
Daikin RXS20K2V1B Service Manual (131 pages)
Inverter Pair Wall Mounted Type FTXS/ATXS-K Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 4.03 MB
Table of Contents
Table of Contents
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Icons Used
10
Part 1 List of Functions
11
Functions
12
Part 2 Specifications
15
Specifications
16
Part 3 Printed Circuit Board Connector Wiring Diagram
21
Indoor Unit
22
Outdoor Unit
24
Rxs20/25K2V1B, Rxs20/25K3V1B, Rxs20/25L2V1B, Arxs25L2V1B
24
Rxs20/25L3V1B, Arxs25L3V1B
26
Part 4 Functions and Control
27
Main Functions
28
Temperature Control
28
Frequency Principle
28
Airflow Direction Control
30
Fan Speed Control for Indoor Unit
31
Program Dry Operation
32
Automatic Operation
33
Thermostat Control
34
NIGHT SET Mode
35
ECONO Operation
35
INTELLIGENT EYE Operation
36
Inverter POWERFUL Operation
37
Clock Setting
38
WEEKLY TIMER Operation
39
Other Functions
45
Thermistor Functions
46
Control Specification
47
Mode Hierarchy
47
Frequency Control
48
Controls at Mode Changing / Start-Up
50
Compressor Protection Function
51
Discharge Pipe Temperature Control
52
Input Current Control
53
Freeze-Up Protection Control
54
Heating Peak-Cut Control
54
Outdoor Fan Control
55
Liquid Compression Protection Function
55
Defrost Control
56
Electronic Expansion Valve Control
57
Pressure Equalizing Control
58
Malfunctions
60
Part 5 Remote Controller
61
Remote Controller
62
Mode Button
63
Quiet Button
63
Part 6 Service Diagnosis
64
General Problem Symptoms and Check Items
65
Troubleshooting with LED
66
Indoor Unit
66
Outdoor Unit
66
Service Diagnosis
67
Troubleshooting
70
Error Codes and Description
70
Indoor Unit PCB Abnormality
71
Freeze-Up Protection Control / Heating Peak-Cut Control
72
Fan Motor (DC Motor) or Related Abnormality
73
Thermistor or Related Abnormality (Indoor Unit)
75
Refrigerant Shortage
76
Low-Voltage Detection or Over-Voltage Detection
78
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
80
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
82
Outdoor Unit PCB Abnormality
83
OL Activation (Compressor Overload)
85
Compressor Lock
87
DC Fan Lock
88
Input Overcurrent Detection
89
Four Way Valve Abnormality
90
Discharge Pipe Temperature Control
92
High Pressure Control in Cooling
93
Compressor System Sensor Abnormality
94
Position Sensor Abnormality
95
DC Voltage / Current Sensor Abnormality
97
Thermistor or Related Abnormality (Outdoor Unit)
98
Electrical Box Temperature Rise
100
Radiation Fin Temperature Rise
101
Output Overcurrent Detection
102
Check
104
Thermistor Resistance Check
104
Indoor Fan Motor Connector Output Check
105
Power Supply Waveforms Check
106
Electronic Expansion Valve Check
106
Four Way Valve Performance Check
107
Inverter Unit Refrigerant System Check
107
Inverter Analyzer Check
108
Rotation Pulse Check on the Outdoor Unit PCB
110
Installation Condition Check
111
Discharge Pressure Check
111
Outdoor Fan System Check
112
Main Circuit Short Check
112
Power Module Check
113
Part 7 Trial Operation and Field Settings
115
Pump down Operation
116
Forced Cooling Operation
117
Trial Operation
118
Field Settings
119
Model Type Setting
119
When 2 Units Are Installed in 1 Room
119
Standby Electricity Saving
120
Facility Setting (Cooling at Low Outdoor Temperature)
120
Jumper Settings
121
Silicone Grease on Power Transistor / Diode Bridge
122
Part 8 Appendix
123
Piping Diagrams
124
Indoor Unit
124
Outdoor Unit
125
Wiring Diagrams
126
Indoor Unit
126
Outdoor Unit
128
Daikin RXS20K2V1B Service Manual (33 pages)
2.0/2.5/3.5 kW Class 9000/12000 Btu/h Class
Brand:
Daikin
| Category:
Air Handlers
| Size: 2.3 MB
Table of Contents
Table of Contents
3
Removal of Outer Panels / Fan Motor
4
Removal of Electrical Box
13
Removal of Pcbs
16
Removal of Reactor / Partition Plate
23
Removal of Sound Blankets
25
Removal of Four Way Valve
27
Removal of Compressor
30
Advertisement
Daikin RXS20K2V1B Installation Manual (20 pages)
Split Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.62 MB
Table of Contents
Safety Precautions
8
Precautions for Selecting the Location
9
Outdoor Unit Installation Drawings
10
Precautions on Installation
11
Outdoor Unit Installation
11
Installation Guidelines
11
Installing Outdoor Unit
11
Refrigerant Piping Work
12
Standby Electricity Saving
15
Pump down Operation
16
Facility Setting (Cooling at Low Outdoor Temperature)
16
Trial Operation and Testing
18
Advertisement
Related Products
Daikin RXS20K3V1B
Daikin RXS20KVLT
Daikin RXS20E2V1B
Daikin RXS20DVMB
Daikin RXS20D2VMB
Daikin RXS20CVMB
Daikin RXS20CVMB9
Daikin RXS20C2VMB
Daikin RXS20J2V1B
Daikin RXS20L3V1B
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL