LIGHTING INSTRUCTIONS

(Reference For Labels 65-0640 & 65-0645)
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance does not have a pilot. It is equipped with an
ignition device that automatically lights the burner. DO NOT
try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
DO NOT try to light any appliance.
DO NOT touch any electric switch; DO NOT use any
phone in your building.
OPERATING INSTRUCTIONS (Label 65-0640)
STOP! Read the safety information above on this label.
Set the thermostat to lowest setting.
Turn off all electric power to the appliance.
This appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the
burner by hand.
Remove control access panel.
Turn gas control knob clockwise
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to next step.
Turn gas control knob counterclockwise
position.
Replace control access panel.
Turn on all electric power to the appliance.
Set thermostat to desired setting.
If the appliance will not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician
or gas supplier.
TO TURN OFF GAS TO APPLIANCE
Set thermostat to lowest setting.
Turn off all electric power to the appliance if service is to be
performed.
Remove control access panel.
Turn gas control knob clockwise
Replace control access panel.
Gas Valve 36E65
30
to "OFF" position.
to "ON"
to "OFF" position.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to turn the gas control knob or depress
and move the gas control selector arm. NEVER use tools. If
the knob will not turn or selector arm will not depress or
move by hand, don't try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire or
explosion.
D. DO NOT use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.
OPERATING INSTRUCTIONS (Label 65-0645)
STOP! Read the safety information above on this label.
Set the thermostat to lowest setting.
Turn off all electric power to the appliance.
This appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the
burner by hand.
Remove control access panel.
Depress and move gas control selector arm left
"OFF" position. Note: Arm cannot be turned to "OFF"
unless arm is pushed in slightly. DO NOT force.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to next step.
Depress and move gas control selector arm right
"ON" position.
Replace control access panel.
Turn on all electric power to the appliance.
Set thermostat to desired setting.
If the appliance will not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician
or gas supplier.
TO TURN OFF GAS TO APPLIANCE
Set thermostat to lowest setting.
Turn off all electric power to the appliance if service is to be
performed.
Remove control access panel.
Depress and move gas control selector arm left
"OFF" position.
Replace control access panel.
to
to
to