LIGHTING INSTRUCTIONS

(Reference For Labels 65-0645)
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, per-
sonal injury or loss of life.
A. This appliance does not have a pilot. It is equipped with
an ignition device that automatically lights the burner. DO
NOT try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electric switch; DO NOT use any
phone in your building.
OPERATING INSTRUCTIONS
STOP! Read the safety information above on this label.
Set the thermostat to lowest setting.
Turn off all electric power to the appliance.
This appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the
burner by hand.
Remove boiler front cover.
Depress and move gas control selector arm left
"OFF" position. Note: Arm cannot be turned to "OFF"
unless arm is pushed in slightly. DO NOT force.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low "B" in the safety information above on this label. If
you don't smell gas, go to next step.
Depress and move gas control selector arm right
to "ON" position.
Replace boiler front cover.
Turn on all electric power to the appliance.
Set thermostat to desired setting.
If the appliance will not operate, follow the instructions
"To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
BOILER JACKET INSTALLATION / REMOVAL
Note: Follow these procedures in reverse to remove parts.
TO INSTALL BOILER ENCLOSURE
• On installations where venting extends out the side
of the enclosure, the appropriate panel (located at
top of jacket sides) should be removed entirely to
allow venting to pass out of enclosure.
• Place enclosure top over top flange of wall panel.
• Slide down until slots (on the insides of enclosure)
are seated in support brackets on mounting panel.
• Attach sheet metal enclosure to wall panel on both
sides with screws.
26
Safe lighting and other performance criteria were met with
the gas manifold and control assembly provided on the boil-
er when the boiler underwent tests specified in ANSI Z21.13.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to depress and move the gas control
selector arm. NEVER use tools. If the selector arm will not
depress or move by hand, DON'T try to repair it, call a
qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. DO NOT use this appliance if any part has been under-
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the con-
trol system and any gas control which has been under-
water.
TO TURN OFF GAS TO APPLIANCE
Set thermostat to lowest setting.
Turn off all electric power to the appliance if service is to
be performed.
Remove boiler front cover.
Depress and move gas control selector arm left
to "OFF" position.
Replace boiler front cover.
to
Gas Valve
7200 DERN
TO INSTALL FRONT COVER
• Insert the slots in cover bottom over support clips on
sheet metal enclosure bottom.
• Line up temperature/pressure indicator through hole
in front cover and push cover in until support clip (at
enclosure top) snaps into slot on cover top.
• Locate 1/4 turn fastener (next to indicator lights) into
receptacle behind front cover and turn in by rotating
1/4 turn only.