Slant/Fin Sentinel SE Series User's Information Manual

Gas boilers with intermittent pilot ignition device system (iid)
Hide thumbs Also See for Sentinel SE Series:

Advertisement

User's Information Manual
Galaxy GG/GX Series, Sentry S/SX Series
and Sentinel SE Series Gas Boilers with
Intermittent Pilot Ignition Device System (IID)
• Before operating this boiler, READ this manual.
• DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable
parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas
supplier for a list of qualified service agencies.
WARNING: If the information in this
manual is not followed exactly, a fire
or explosion may result causing
property damage, personal injury or
loss of life.
— DO NOT store or use gasoline or
other flammable vapors and liquids in
the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch;
DO NOT use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
If your boiler is purchased with or will be equipped with an automatic vent damper, make certain that the
damper is installed and wired by a qualified installer who has been certified by your local gas utility. See
Vent Dampers page 7.
Keep the boiler area clean and free of all materials that can burn.
NEVER close or reduce openings that supply air for the boiler fire and for ventilation.
Your gas boiler must be installed and serviced by a qualified service agency or
gas supplier. The lack of proper service can result in a dangerous condition.
Printed in U.S.A. 1198
FOR YOUR SAFETY:
DO NOT use this boiler if any part has
been underwater. Immediately call a quali-
fied service technician to inspect the boil-
er and to replace any part of the control
system and any gas control which has
been underwater.
Should overheating occur or the gas
supply fail to shut off, DO NOT turn off
or disconnect the electric supply to the
circulator pump. Instead, shut off the
gas supply at a location EXTERNAL to
the appliance.
SLANT/FIN DOES NOT PERMIT THE USE OF VENT
DAMPERS ON BOILERS EQUIPPED WITH MILLI-
VOLT IGNITION SYSTEMS. OTHER VENT
DAMPERS OR DEVICES WITH SIMILAR PURPOSE
ARE NOT PERMITTED.
WARNING
WARNING
PUBLICATION NO. GS-UIM-IID
Part No. 41-1825

Advertisement

loading

Summary of Contents for Slant/Fin Sentinel SE Series

  • Page 1 DO NOT use any phone in your building. WARNING • Immediately call your gas supplier SLANT/FIN DOES NOT PERMIT THE USE OF VENT from a neighbor's phone. Follow the DAMPERS ON BOILERS EQUIPPED WITH MILLI- gas supplier's instructions. VOLT IGNITION SYSTEMS. OTHER VENT •...
  • Page 2 SENTRY “S” SERIES BOILER SENTINEL “SE” and WITH INTEGRAL DRAFT DIVERTER SENTRY “SX” SERIES BOILER WITH EXTERNAL DRAFT HOOD Figure 1. MODEL S-34 Figure 3. MODELS SE-70 through SE-245 MODELS SX-150 through SX-210 Figure 2. MODELS S-60 through S-150 Figure 4. BASE ASSEMBLY Typical for all Sentry and Sentinel models Burners Pilot...
  • Page 3 SENTINEL “SE” and SENTRY “S & SX” SERIES BOILERS GENERAL DIMENSIONS, LOCATIONS AND IDENTIFICATION OF PARTS MODELS SX-150 to SX-210 and SE-70 to SE-245 * Vent damper may be installed horizontally on all models with use of a vent elbow. See lighting instructions on page 8.
  • Page 4 GALAXY GG/GX SERIES BOILER Location and identification of parts Figure 14. GG Series—Hot Water Boiler Temperature Relief Valve and Pressure Gauge Jacket Top Name and Rating Plate Lighting Instructions (inside front panel) Gas Valve Burner Access Door Gas Manifold Burners Figure 15.
  • Page 5 Inspection, cleaning, repair— (3A) On water boilers: The temperature and pressure gauge indicates the Chimney, flue pipe and boiler pressure in the boiler at each water temperature. For Your boiler and heating system will last an indefinitely most installations, it should indicate about 12 to 15 long time at full efficiency, if it is inspected regularly psi pressure when temperature is about 70 to 100 and is kept in good repair and adjustment.
  • Page 6: Service Inspection

    (b) This device must be installed and inspected annu- ally by a qualified installer in accordance with the Slant/Fin vent damper installation instructions. If improperly installed, a hazardous condition such as explosion or carbon monoxide poisoning could result.
  • Page 7 VENT DAMPERS IGNITION SYSTEM—IID Your gas boiler is equipped with the Honeywell INTER- A Slant/Fin vent damper is available only as part of a MITTENT PILOT IGNITION DEVICE (IID) System Slant/Fin gas boiler package equipped with a 24 volt gas (Intermittent Spark Ignited Pilot) INCORPORATING GAS valve.
  • Page 8: Safety Information

    DO NOT try to Gas To Appliance" and call your service technician or light the pilot by hand. gas supplier. SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600 FAX: (516) 484-5921 • Canada: Slant/Fin , Mississauga, Ontario LTD/LTEE ®...