Toshiba RAS-M10PKVP-E Service Manual page 87

Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

D800
D801
Before check
During check
Check results
LED
D802
D803
D804
D805
– 87 –
: LED ON,
: LED OFF,
Description
Normal operation (no error)
Checking A unit
Checking B unit
Checking C unit
Normal operation (no error)
Trouble in unit A
Trouble in unit B
Trouble in unit C
Trouble in unit A and B
Trouble in unit A and C
Trouble in unit A
Trouble in unit B and C
Trouble in unit B
Trouble in unit C
Trouble in unit A,B and C
Trouble in unit A,B
Trouble in unit A,C
Trouble in unit B,C
Trouble in unit A,B,C