Toshiba RAS-M10PKVP-E Service Manual page 79

Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Piping on the bottom right or the bottom
left
• After making slits on the front panel with a knife or
similar tool, cut them out with a pair of nippers or
an equivalent tool.
Slit
Fig. 10-3-16
Left-hand connection with piping
Bend the connecting pipes so that they are
positioned within 43 mm above the wall surface.
If the connecting pipes are positioned more than
43 mm above the wall surface, the indoor unit may
be unstable.
When bending the connecting pipe, make sure to
use a spring bender to avoid crushing the pipe.
Refer to the table below for the bending radius
of each connection pipe.
Outer diameter
6.35 mm
9.52 mm
12.7 mm
Connect the pipe after installation of the
unit (figure)
270 mm
Gas side
230 mm
Liquid side
R30 or less (Dia. 6.35), R40 or less (Dia. 9.52), R50 or less (Dia. 12.7)
Make sure to use a spring bender to avoid crushing the pipe.
Outward form of indoor unit
Use a screwdriver handle, etc.
Fig. 10-3-17
NOTE
If the pipe is incorrectly bent, the indoor unit may be
unstable on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipe to the auxiliary pipes
and wrap the facing tape around them.
Bending radius
30 mm
40 mm
50 mm
(To the front flare)
CAUTION
• Bind the auxiliary pipes (two) and connecting cable
with facing tape tightly.
In case of leftward piping and rear-leftward piping,
bind the auxiliary pipes (two) only with facing tape.
Auxiliary pipes
Installation plate
• Carefully arrange the pipes so that none of the pipes
stick out of the rear plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting
pipes to each other and cut off the insulating tape
wound on the connecting pipe to avoid double-taping
at the joint, moreover, seal the joint with the vinyl
tape, etc.
• Since condensation can result in machine
performance trouble, be sure to insulate both
connecting pipes.
(Use polyethylene foam as insulating material.)
• When bending a pipe, be careful not to crush it.
– 79 –
Indoor unit
Connecting
cable
Fig. 10-3-18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m18pkvp-eRas-3m26uav-eRas-m13pkvp-eRas-m16pkvp-e

Table of Contents