Temporary Operation; Air Purifying Control; Purpose - Toshiba RAS-M10PKVP-E Service Manual

Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
12. Temporary
Pushing [RESET] button starts the temporary
operation
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more,
the temporary [COOL] operation is performed.
PURE indicator (Orange) ON
NO
Did you push [RESET] button
for 3 seconds or more?
YES
Did you push [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.

13. Air purifying control

Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Louver swing is available
Air purifying operation
AC + Air purifying operation
NOTE When the previous operation was the operation of air conditioner + air purifier, an operation of air conditioner + air purifier
starts by pushing AC button on the remote controller. (Operation of air conditioner + air purifier is stored in memory.)
Sending air purifier-ON
[1] Air conditioner stops
Operation indicator ON
PURE indicator ON
Louver Open memory
position (Cooling)
Moving panel Open
Fan ON
Air purifier ON
Air purifying operation
Fan speed at Fan Auto mode.
YES
Push RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
AC operationAC
Fan speed *1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
Follows to AC operation
[1], [2]
[2] Air conditioner
operates
PURE indicator ON
Air purifier ON
Air conditioner +
air purifier operation
1) When pushing [RESET] button, the temporary
[AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, "beep, beep, beep" sound is
heard and [AUTO RESTART] control is changed.
3) When keeping [RESET] button pushed for
10 seconds or more, "beep" sound is heard and
the temporary [COOL] operation starts.
4) If the filter lamp goes on, push [RESET] button to
go off the filter lamp, and then push [RESET]
button again.
5) To stop the temporary operation, push the button
again.

1. Purpose

This function generates negative ion while
cleaning the air in the room.
The air purifying control function is to alert the
user that something is wrong in the ionizing or air
purifying operation.
All stop
If air purifier-ON signal is received while the air
All stop
conditioner stops, the air purifier starts operation,
and if it is received while the air conditioner
operates, the air conditioner and the air purifier
start operation.
The air ion generator operates linked with the air
purifying operation.
Sending air purifier-OFF
[3] Air purifier operates
Operation indicator OFF
PURE indicator OFF
Fan OFF
Air purifier OFF
Louver close
All stop
Fan speed level
– 60 –
Description
[3], [4]
[4] Air conditioner +
Air Purifier operation
PURE indicator OFF
Air purifier OFF
Air conditioner operates
: Hi Power
min

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m18pkvp-eRas-3m26uav-eRas-m13pkvp-eRas-m16pkvp-e