TIME CODE

This menu sets the time code.
Item
FR
SUPER
No.
DISP.
0000
0001
500
VITC BLANK
59.94 Hz, 29.97 Hz
0000
0006
0010
501
VITC POS-1
0000
0004
0015
59.94 Hz, 29.97 Hz
0000
0008
0010
502
VITC POS-2
0000
0006
0015
0000
0001
504
RUN MODE
Setting
FR
SUPER
No.
DISP.
BLANK
59.94Hz
THRU
Specifies whether or not a VITC signal will be output at the positions selected in setup
menu No. 501 (VITC POS-1) and No. 502 (VITC POS-2) during playback.
0: VITC signals are not output.
1: VITC signals are output.
NOTE:
• This setting is available only during analog composite output and SD SDI output.
• In EE mode, the input signal is output with the VITC signal.
When set to
59.94Hz
Specifies the position where the VITC signal will be inserted.
10L
NOTE:
|
|
• You cannot select the same line as in setup menu No. 502 (VITC POS-2).
16L
• The VITC signal is not output when 23.98, 24, 59-23, 60-24, or 60-25 is selected in
|
|
setup menu No.25 (SYSTEM FREQ).
20L
• You cannot select the same line as in setup menu No.692 (UMID POS).
When set to
• This setting is available only during analog composite output and SD SDI output.
50 Hz, 25 Hz
• This setting does not return to factory default even if you press the SEARCH button
and RESET button simultaneously.
7L
|
|
11L
|
|
22L
When set to
59.94Hz
Specifies the position where the VITC signal will be inserted.
10L
NOTE:
|
|
• You cannot select the same line as in setup menu No. 501 (VITC POS-1).
18L
• The VITC signal is not output when 23.98, 24, 59-23, 60-24, or 60-25 is selected in
|
|
setup menu No.25 (SYSTEM FREQ).
20L
• You cannot select the same line as in setup menu No.692 (UMID POS).
When set to
• This setting is available only during analog composite output and SD SDI output.
50 Hz, 25 Hz
• This setting does not return to factory default even if you press the SEARCH button
and RESET button simultaneously.
7L
|
|
13L
|
|
22L
REC
Specifies an operating mode that advances the internal time code generator.
0: The internal time code generator is advanced only during recording.
FREE
1: When the power is on, the internal time code generator is advanced regardless of
operating mode.
NOTE:
When setup menu No. 040 (VFR REC) is set to ON, the time code advances only during
recording even when FREE is selected.
• XX indicates factory default settings.
Settings and brief function description
50Hz
29.97Hz
25Hz
50Hz
29.97Hz
25Hz
50Hz
29.97Hz
25Hz
only
only
only
Setup: Item Settings
181