Viessmann Vitocal 242-S Installation And Service Instructions Manual page 58

Compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for Vitocal 242-S:
Table of Contents

Advertisement

Installation sequence
Electrical connection
Internal unit: AVI PCB
Interface internal unit – external unit
Plug
Component
F101
Fuse 1.0 AL (slow)
P202
BUS connection (12 V to external unit for type AWT-AC 241.A10 and
A13)
P203
BUS connection (43 V to external unit for type AWT-AC 241.A04 and
A07)
Note
■ Only one BUS connection should be
connected.
■ Do not interchange the BUS connec-
tion wires between the internal and
external units.
■ Route the BUS connecting cable in the
230 V~ voltage area.
58
(cont.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents