Viessmann Vitocal 242-S Installation And Service Instructions Manual page 136

Compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for Vitocal 242-S:
Table of Contents

Advertisement

Specification
Specification
Vitocal 242-S, Type AWT-AC (230 V~)
Type AWT-AC
Heating output data
At 100 % according to
EN 14511
(A2/W35 °C, spread 5 K)
Rated heating output
Compressor frequency
Fan speed
Power consumption
Coefficient of perform-
ance ε (COP) in heating
mode
Output control
Heating output data
At 100 % according to
EN 14511
(A7/W35 °C, spread 5 K)
Rated heating output
Compressor frequency
Fan speed
Air flow rate
Power consumption
Coefficient of perform-
ance ε (COP) in heating
mode
Cooling performance data
At 100 % according to
EN 14511
(A35/W7 °C, spread 5 K)
Rated cooling capacity
Compressor frequency
Fan speed
Power consumption
Energy efficiency ratio
EER
Output control
136
241.A04
kW
3.0
Hz
60
rpm
870
kW
0.91
3.30
kW
1.1 – 3.8
kW
4.5
Hz
60
rpm
870
2090
3
m
/h
kW
0.97
4.64
kW
3.2
Hz
60
rpm
870
kW
1.08
2.96
kW
1.2 – 3.8
241.A07
241.A10
5.6
65
650
650
1.73
2.20
3.24
3.50
1.3 – 7.7
4.4 – 9.9
8.39
10.9
65
650
650
3600
4210
1.96
2.36
4.28
4.62
6.2
65
650
650
2.40
2.69
2.58
2.75
1.6 – 8.0
2.4 – 8.5
241.A13
7.7
10.6
55
75
650
3.25
3.26
5.0 – 11.9
14.6
55
75
650
4210
3.40
4.29
7.4
9.1
55
70
650
3.64
2.50
2.4 – 10.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents