Viessmann Vitocal 242-S Installation And Service Instructions Manual page 34

Compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for Vitocal 242-S:
Table of Contents

Advertisement

Installation sequence
Connecting refrigerant lines
D
Hot gas line
Insulation against noise and vibrations with entry points above ground level
Note
Route connecting cables and refrigerant lines separately.
A Pipe bends as vibration compensa-
tors
B Clips with EPDM lining
C Cable entry, e.g. drainage pipe with
thermal insulation
34
(cont.)
E
Oil lift bends
,
Flow direction for heating mode
,
Flow direction for cooling mode
A
D Electrical cables/leads, internal/
external unit
B
C
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents