Tissue calculation model:
Suunto RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc,
PhD)
9 tissue compartments
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes
(on gassing). The off gassing halftimes are slowed down
Helium halftimes:1, 2, 3.5, 7.5, 15, 30, 45, 90, 181 minutes (on gassing). The off
gassing halftimes are slowed down.
Reduced gradient (variable) "M" values based on diving habit and dive violations.
The "M" values are tracked up to 100 hours after a dive
The EAN and oxygen exposure calculations are based on recommendations by
R.W. Hamilton, PhD and currently accepted exposure time limit tables and prin-
ciples.
Battery:
One 3 V lithium battery: CR 2450
Battery storage time (shelf life): Up to three years
Replacement: Every two years, or more often depending on dive activity
Life expectancy at 20°C/68°F:
0 dives/year –> 2 years
100 dives/year –>1.5 years
300 dives/year –>1 year
Transmitter:
One 3V lithium battery: 1/2AA (K5546) and O-ring 2.00 mm x 2.00 mm (K5538)
Battery storage time (shelf life): Up to three years
Replacement: Every two years, or more often depending on dive activity