4.2.18 Fuser Assy
Note! Replace the Fuser-Assy by Assy unit.
It is forbidden for disassembling the Fuser-Assy, also, reusing the
disassembled Fuser-Assy.
(1) Remove the Frame Assy TR. (Refer to 4.2.11)
(2) Remove the Scanner unit. (Refer to 4.2.8)
(3) Remove the Cover Assy Stacker. (Refer to 4.2.16)
(4) Remove the screw (Silver)
(5) Remove the screw (Black)
(FFC)
from Guide Cable
44871001TH Rev.6
and remove the FG-Cable
from Guide Cable
and the screw (Silver)
, and remove FG_Film
.
(6) Remove the Guide Cable
.