Testbox
The test box, no. 6420100, is an indispensable tool, especially when the pro blem is intermittent. Further
to the in for ma ti on on this pa ge there is mo re in for ma ti on in Ser vi ce/Technical In for ma ti on no. 56.
Flame sensor and magnet
coil. Light green when they
are active (burning)
Press the button Y1. Gives a direct
signal to the oil spool and by-pas-
ses by that the safety system.
NB:
When the test box is connected, the fl ame sen sor is disconnected the safety sy stem. The
mac hi ne is therefore not stop ping automatically, although the fl ame sen sor is defect.
36
Temperature sensors
green light
- they are ok
yellow light
- they are short-circuited
red light
- they are disconnected
Only to be used on the ma-
chine with electric motor
Test/adjustment
The test box is mounted directly in the plug of the
PC-board. Ac cess to this is gained by loosening the
front plate at shown.
The but ton at the top left-hand corner is set at 09
(mac hi ne with fl ame sen sor). Water is fi l led into the
mac hi ne, and hoses are connected. The mac hi ne is
set at 150C and started.
Flow control lamp shows a
green light, when the fl ow
switch gives a signal
At failing signal the button in
question is pressed, and the
fl ow switch is by-passed
Voltage indicator,
green light
yellow light
red light
F
- voltage ok
- voltage low
- voltage high