Why Nothing Should Be Placed Against The Heater; Wiring Diagram - Lopi Spirit B-Vent Gas Stove Owner's Manual

Wood gas pellet b-vent gas stove
Table of Contents

Advertisement

Why Nothing Should Be Placed Against the Heater

Your heater has a grill below the ashlip and openings along the top and back that must not be
blocked. The grill area allows air into the firebox. If it is blocked the combustion inside the
firebox will not burn normally. This will result in reduced efficiency and the exhaust gases will
become dirty. The convection air openings along the top and back draw room air over the hottest
parts of the heater and distribute the warmed air into the room. If they are blocked, the heater
will not heat as well and may become too hot internally.

Wiring Diagram

Spill Switch
Thermodisk
Brown
Optional
Thermostat
Gas Control Valve
EPU
terminal
Red
Red
Jumper Wire
Green
(Manual
Operation)
Optional
Remote
Control
T
ROUBLESHOOTING
Thermopile
Red
White
Red
On/Off
Switch
Chassis
Blower
Ground
Motor
Black
Black
White
White
Black
Blower
Thermodisk
(C
ONTINUED
Piezo Igniter
Orange
Thermocouple
Copper Co-Axial Wire
Green
White
120 Volt
Grounded A.C.
Power Supply
Black
Black
110 V.
Blower
Blower
Circuit
Rheostat
)
P