Heater Placement Requirements
Heater must be installed on a level surface capable of supporting the heater and vent.
•
Due to the high temperature, the heater should be located out of traffic and away from furniture
•
and draperies.
When placed in a location where the floor to ceiling height is under 7 feet (2.134 M), the
•
installation is considered an alcove and must meet the following requirements:
The alcove floor to ceiling height must be at least 58" (1474mm) tall
-
The alcove must not be more than 45" (1143) deep before the ceiling returns to 7' (2134mm).
-
The alcove must be at least 46-3/4" (1188mm) wide
-
The heater must not be placed so the vents below or above the door, along the sides of heater, or
•
along the back of the heater can become blocked.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
•
appliance produces when determining a location.
Floor Protection Requirements
When the stove is installed directly on carpeting, vinyl or other combustible material other than
•
wood flooring or a high pressure laminate wood floor, the stove must be installed on a metal or
wood protection panel extending the full width and depth of the heater (Minimum 26-3/4"
(680mm) wide by 19" (483) deep).
Electrical Requirements
Plug the stove into a grounded receptacle supplying a minimum 1.5 amps (115 Volts, 60 Hz, 180
•
watts).