REPLACING THE BOWDEN CABLE

(Only without option drum brake)
Note:
The pressure spring (fig. 3–15/ A) at the counter plate
serves for the reduction of the brake lever way and
expands the optimal area of effectiveness of the air
installation.
Removal
– Remove the counter nut (fig. 3–16/ B) from the ad-
justment screw at the counter plate. Pull back the
adjustment screw (fig. 3–16/ C) and lift the bowden
cable out through the slot.
– Unscrew the counter nut (fig. 3–17/ D) from the
adjustment screw at the brake lever. Pull back the
adjustment screw (fig. 3–17/ E) and lift the bowden
cable out through the slot.
Remove the starlock quick fasteners (fig. 3–18/ F) from
the eccentric (fig. 3–18/ G) and pull the eyelet (fig.
3–18/ H) at the end of the bowden cable from the
eccentric.
– Screw the eye screw (fig. 3–18/ I) off of the frame
and remove it together with the complete bowden
cable.
Fitting
The fitting is done analogue in reverse order.
Attention:
!
The starlock quick fastener has to be replaced un-
der all circumstances. During fitting you have to
watch for the professional assembly of the starlock
quick fastener.
Note:
The eye screw has to aligned before fitting so that
the bowden cable is not bent at the adjustment
screw.
After fitting the bowden cable must be adjusted again.
3–15
C
3–16
E
3–17
I
3–18
A
B
D
G
H
F
17