FireplaceXtrordinair 36 DV XL Owner's Manual page 48

Built-in direct vent fireplace
Hide thumbs Also See for 36 DV XL:
Table of Contents

Advertisement

4 8
6
Follow the directions below to wire the blower box.
a
Remove the cover from
the blower box.
Attach the hot (black) and common (white) wires to the
c
leads coming from the wires (use wire nuts).
7
Follow the directions below to wire the rheostat. NOTE: There are two types of junction boxes,
use the appropriate junction box for your installation.
Force the sheathed cable through
a
one of the locking flaps on the
junction box (repeat for the other
cable). Some force is needed.
The flap will lock the cable in place.
From
Blower Box
To
Fireplace
Travis Industries
Optional Equipment
Phillips
Screwdriver
d
Attach the common (white) wires
b
together. Attach the ground
(exposed or green) wires together.
Then attach each of the hot (black)
wires from the cables to the two
wires on the rheostat (orientation
does not matter). Carefully pack
NOTE:Two junction
the wires into the junction box.
boxes are included -
use the best box for
your installation.
9 3 5 0 8 1 0 3
b
Insert sheathed cable through the cable clamp.
After the wires have been connected tighten the
clamp to secure the cable.
Secure the ground wire to the ground stud inside the
blower box by tightening the included nut over the
ground wire. Re-attach the cover removed in step
"a".
Ground Wire
Standard
Screwdriver
Attach the cover plate
c
(either white or beige) with
the included screws. Slide
the knob (either white or
beige) over the rheostat
shaft.
Standard
Screwdriver
1 5 1 0 0 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents